首页> 外文期刊>Lasers in Medical Science >A novel LED-based device for occlusal caries detection
【24h】

A novel LED-based device for occlusal caries detection

机译:一种基于LED的新型咬合龋检测设备

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this in-vitro study was to compare the performance of laser-based (DIAGNOdent, KaVo, Biberach, Germany) and LED-based (Midwest Caries I.D., DENTSPLY Professional, New York, USA) caries detectors in the detection of occlusal caries in permanent molars. The study consisted of 129 visually sound or non-cavitated pits or fissures in 82 extracted permanent human molar teeth. Two trained examiners used the laser-based and LED-based caries detectors to examine the fissures for caries. The teeth were then sectioned at the surfaces suspected of containing occlusal caries and histologically evaluated using stereomicroscopy as a gold standard. Inter-examiner reliability of the caries detector examination was assessed using Cohen’s Kappa statistics. The sensitivity, specificity, and accuracy in diagnosing occlusal caries using the two devices were calculated according to appropriate cut-off scores. Receiver operating characteristic (ROC) curves were also determined to compare the diagnostic performance of the devices in occlusal caries diagnosis. The cut-off level of significance was taken as p = 0.005. Cohen’s Kappa showed substantial agreement for the laser-based caries detector (0.74), and almost perfect agreement for the LED-based (0.89) caries detector. The specificity of the laser-based device varied from 0.49 to 0.97 at T1 and T2. Its sensitivity varied from 0.33 to 0.65 at T1 and T2. The specificity of the LED-based device varied from 0.48 to 0.56 at T1 and T2. Its sensitivity varied from 0.65 to 0.84 at T1 and from 0.80 to 0.84 at T2. Taking the limitations of the current study into consideration, the DIAGNOdent laser pen was more accurate in determining when teeth were free of occlusal caries than was the Midwest Caries I.D. LED-based device, although the Midwest Caries I.D. device more often revealed the presence of occlusal caries than did the DIAGNOdent pen.
机译:这项体外研究的目的是比较基于激光的龋齿检测仪(DIAGNOdent,KaVo,Biberach,德国)和基于LED的龋齿检测仪(Midwest Caries ID,DENTSPLY Professional,美国纽约)的性能。永久磨牙中的龋齿。该研究包括82个拔出的人类恒牙臼齿中的129个视觉上可见或无空洞的凹坑或裂缝。两名训练有素的检查员使用基于激光和基于LED的龋齿检测器检查龋齿。然后将牙齿切成疑似含有咬合龋的表面,并使用体视显微镜作为金标准进行组织学评估。使用Cohen的Kappa统计数据评估了龋齿检测器检查的检查者间可靠性。根据适当的截断分数,计算使用这两种设备在诊断咬合龋方面的敏感性,特异性和准确性。还确定了接收器工作特性(ROC)曲线,以比较该设备在咬合龋诊断中的诊断性能。显着性的临界水平设为p = 0.005。科恩(Cohen)的Kappa对基于激光的龋齿检测器(0.74)表示出了实质性的同意,而对于基于LED的龋齿检测器(0.89)则表现出近乎完美的协议。基于激光的设备的特异性在T1和T2时从0.49到0.97不等。在T1和T2时,其灵敏度从0.33到0.65不等。基于LED的设备的特异性在T1和T2时从0.48到0.56不等。其灵敏度在T1时从0.65到0.84,在T2时从0.80到0.84。考虑到当前研究的局限性,DIAGNOdent激光笔在确定牙齿何时没有咬合龋方面比中西部龋齿I.D.更准确。基于LED的设备,尽管Midwest Caries I.D.与DIAGNOdent笔相比,该设备更经常显示出咬合龋的存在。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号