Arthroscopic fixation of anterior cruciate ligament tibial avulsion fractures using bioabsorbable suture anchors

机译:使用生物可吸收缝合锚钉的关节镜固定前交叉韧带胫骨撕脱性骨折

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This article describes a new technique for the arthroscopic reduction and fixation of anterior cruciate ligament (ACL) tibial avulsion fractures using bioabsorbable suture anchors. This described technique requires the use of anterolateral, anteromedial, medial mid-patellar, and lateral mid-patellar portals. A suture hook loaded with No. 2 polydioxanone (PDS) was used to pierce the ACL through the anteromedial or anterolateral portal, and bioabsorbable suture anchors were inserted through the medial and lateral mid-patellar portals. The five patients treated using this technique were evaluated at 1 year postoperatively. All patients showed bony union without anterior laxity or flexion contracture. The described technique provides firm fixation of fracture fragment and can be used in both skeletally immature and mature patients.
机译:本文介绍了一种使用生物可吸收缝合锚钉在关节镜下复位和固定前交叉韧带(ACL)胫骨撕脱性骨折的新技术。此描述的技术需要使用前外侧,前内侧、,中内侧和lateral中外侧门。使用装有2号聚二恶烷酮(PDS)的缝合线钩刺穿ACL穿过前内侧或前外侧门,将可吸收生物的缝合锚钉穿过内侧和外侧mid骨中门插入。术后1年评估使用该技术治疗的5例患者。所有患者均表现为骨性愈合,无前路松弛或屈曲挛缩。所描述的技术可牢固固定骨折片段,可用于骨骼不成熟和成熟的患者。