首页>
外文期刊>日本建築学会计画論文集
>The Hygrothermal Environment in the Crawl Space Insulated on Foundation Wall in the Summer Involving Rainy Season Study on vertical edge insulation method for the moderate And humid climate region Part 2
【24h】
The Hygrothermal Environment in the Crawl Space Insulated on Foundation Wall in the Summer Involving Rainy Season Study on vertical edge insulation method for the moderate And humid climate region Part 2
To clarify the hygrothermal environment of vertical edge insulation methods in moderate and humid climate region, especially in the summer involving the rainy season, temperature and relative humility of 12 houses have been measured. From the measurement results, the temperature variation in the crawl space tends to slide slightly backward compare to the outdoor air. Evaporation from the drying concrete keeps the humidity in the crawl space rather high, especially in the summer just after completion.
展开▼