首页> 外文期刊>Journal of Ultrasound >Impact of umbilical cord length on fetal circulatory system by Doppler assessment
【24h】

Impact of umbilical cord length on fetal circulatory system by Doppler assessment

机译:多普勒评估脐带长度对胎儿循环系统的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction Numerous studies have revealed the impact of umbilical cord (UC) length on fetal perfusion; abundant data implicate abnormal UC length to neurological delay and subsequent poor prognoses for fetuses and newborns. Indeed, our group previously developed theoretical approximations that contributed to formulas capable of explaining the impact of UC length on cardiac output. Methods We performed an observational study that measured the pulsatility index and flow velocity in umbilical arteries. A special Doppler measured proximal and distal indexes in both arteries. After birth, medical staff measured complete UC length. We obtained maternal and neonatal outcomes from clinical records. Results Our study enrolled 20 pregnant mothers. We found that flow velocities in the two edges were different: fetal edges exhibited greater velocity in the majority of cases; but, when we compared pressure differentials (ΔP), the pulsatility index was significantly related to umbilical cord length. Conclusions Fetal perfusion, welfare, and viability are related to UC function as the conveyor of all fetal volemia. Excessive UC length affects cardiac dynamics and increases peripheral vascular resistance. Further studies could validate routine use of the differential proximal and distal measurements proposed in this article, and their implications in in utero fetal heart function. We also hope that early diagnosis or UC alterations could alert neonatologists and obstetricians to clinical conditions of the fetus.
机译:引言众多研究揭示了脐带(UC)长度对胎儿灌注的影响;丰富的数据暗示异常的UC长度与神经延迟和随后的胎儿和新生儿的贫困预期。实际上,我们的小组以前开发了有助于解释UC长度对心脏输出影响的公式的理论近似。方法我们进行了一种观察性研究,该研究测量了脐动脉中的脉动性指数和流速。一种特殊的多普勒在两个动脉中测量近端和远端指标。出生后,医务人员测量完整的UC长度。我们从临床记录中获得了孕产妇和新生儿结果。结果我们的研究注册了20名怀孕的母亲。我们发现两个边缘中的流速不同:胎儿边缘在大多数情况下表现出更大的速度;但是,当我们比较压差(ΔP)时,脉动性指数与脐带长度显着相关。结论胎儿灌注,福利和活力与UC功能有关,作为所有胎儿血型血症的输送机。过度的UC长度会影响心动力学并增加外周血管血管阻力。进一步的研究可以验证本文提出的差异近端和远端测量的常规用途,以及它们在子宫胎心功能中的影响。我们还希望早期诊断或UC改变可以提醒新生素学家和产科医生对胎儿的临床条件。

著录项

  • 来源
    《Journal of Ultrasound》 |2020年第4期|585-592|共8页
  • 作者单位

    Pathology Department Hospital Universitario San Ignacio Pontificia Universidad Javeriana Bogota Colombia Hospital Universitario San Ignacio Kra 7 40‑62 Bogota Colombia;

    Forensic Physics Group Instituto Nacional de Medicina Legal y Ciencias Forenses Bogota Colombia;

    Obstetrics and Gynecology Department Hospital Universitario San Ignacio Pontificia Universidad Javeriana Bogota Colombia Hospital Universitario San Ignacio Kra 7 40‑62 Bogota Colombia;

    Pontificia Universidad Javeriana Bogota Colombia Hospital Universitario San Ignacio Kra 7 40‑62 Bogota Colombia;

    Pontificia Universidad Javeriana Bogota Colombia Hospital Universitario San Ignacio Kra 7 40‑62 Bogota Colombia;

    Pontificia Universidad Javeriana Bogota Colombia Hospital Universitario San Ignacio Kra 7 40‑62 Bogota Colombia;

    Pontificia Universidad Javeriana Bogota Colombia Hospital Universitario San Ignacio Kra 7 40‑62 Bogota Colombia;

    Instituto de Genetica Humana Pontificia Universidad Javeriana Bogota Colombia;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Umbilical cord; Umbilical cord length; Stillbirth; Thrombosis; Physics;

    机译:脐带;脐带长度;死胎;血栓形成;物理;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号