首页> 外文期刊>Journal of Thermal Analysis and Calorimetry >Thermal decomposition analysis of organic peroxides using model-free simulation
【24h】

Thermal decomposition analysis of organic peroxides using model-free simulation

机译:使用无模型模拟对有机过氧化物进行热分解分析

获取原文
获取原文并翻译 | 示例

摘要

To understand better the thermal decomposition characteristics of organic peroxides, a C80 heat flux calorimeter was used and the decomposition pattern of cumene hydroperoxide and di-tert-butylperoxide were classified as auto-catalytic and n th order reaction, respectively. Based on the scanning results with the C80 at several differing rates of heating, the thermal decomposition behavior of organic peroxides under isothermal storage at lower temperature was simulated with a model-free simulation. Simulated results showed that the calculated conversion of cumene hydroperoxide as a function of time was in good agreement with experimental data obtained with the TAM-III high sensitivity thermal activity monitor.
机译:为了更好地理解有机过氧化物的热分解特性,使用了C80热通量热分析仪,并将异丙苯氢过氧化物和二叔丁基过氧化物的分解模式分别分类为自催化和n阶反应。基于C80在几种不同加热速率下的扫描结果,采用无模型模拟对有机过氧化物在较低温度下等温储存下的热分解行为进行了模拟。模拟结果表明,所计算的氢过氧化枯烯的转化率与时间的关系与使用TAM-III高灵敏度热活性监测仪获得的实验数据非常吻合。

著录项

  • 来源
    《Journal of Thermal Analysis and Calorimetry》 |2008年第2期|407-411|共5页
  • 作者单位

    Department of Safety Engineering Yokohama National University Tokiwadai Hodogaya-ku Yokohama 240-8501 Japan;

    Department of Safety Engineering Yokohama National University Tokiwadai Hodogaya-ku Yokohama 240-8501 Japan;

    Science and Technology Research Center Mitsubishi Chemical Co. Ltd. Kamoshida Aoba-ku Yokohama 236-8501 Japan;

    Science and Technology Research Center Mitsubishi Chemical Co. Ltd. Kamoshida Aoba-ku Yokohama 236-8501 Japan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    model-free simulation; organic peroxide; thermal decomposition;

    机译:无模型模拟有机过氧化物热分解;