A full-scale experimental program consisting of testing four as-built diaphragms and four retrofitted diaphragms in both principal loading directions is presented. As-built configurations were typical of those found in historic unreinforced masonry buildings in North America and Australasia, whereas retrofitted diaphragms consisted of plywood panel overlays with stapled sheet metal blocking systems (SMBS). Test results were characterized using bilinear representations to establish recognizable performance parameters such as shear strength, shear stiffness, and ductility capacity, which were then used for comparative analysis. The nonlinear and low stiffness behavior of as-built diaphragms was confirmed in each principal loading direction. The plywood overlay and SMBS dramatically improved as-built diaphragm shear strength and shear stiffness and were shown to perform satisfactorily from a serviceability perspective. The orthotropic nature of as-built diaphragms was proven, with perpendicular-to-joist shear stiffness being as low as 68% of the corresponding orthogonal value. A typical duly framed stairwell penetration and discontinuous joists with two-bolt lapped connections were shown to have no detrimental impact on tested diaphragm performance. Predicted diaphragm performance using state-of-art assessment documents was shown to be inconsistent with corresponding values established from testing. It is recommended that these assessment procedures be updated with revised performance parameters and provisions to address diaphragm orthotropic behavior.
机译:提出了一个全面的实验程序,包括在两个主要载荷方向上测试四个成品膜片和四个翻新膜片。竣工配置是在北美和澳大拉西亚历史悠久的未加固砌体建筑中发现的典型配置,而翻新的隔板则由胶合板面板覆盖层和订书钉金属阻挡系统(SMBS)组成。使用双线性表示来表征测试结果,以建立可识别的性能参数,例如剪切强度,剪切刚度和延展性,然后将其用于比较分析。在每个主载荷方向上都确认了已建膜片的非线性和低刚度行为。胶合板覆盖层和SMBS显着提高了成品隔膜的抗剪强度和抗剪刚度,从可维修性的角度来看,它们的性能令人满意。膜片的正交各向异性已得到证明,垂直至梁的剪切刚度低至相应正交值的68%。结果表明,典型的适当构架的楼梯间穿透力和带有两个螺栓搭接连接的不连续托梁对测试的膜片性能没有不利影响。使用最新的评估文件预测的膜片性能被证明与测试中确定的相应值不一致。建议使用修订后的性能参数和规定来更新这些评估程序,以解决膜片正交各向异性行为。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号