One series of five composite joints with welded connections was tested and the influences of joint type, slab thickness, and number of shear studs were studied. Welded unreinforced flange with bolt web and reduced beam section connections were included. Load-resisting mechanism, failure mode, energy absorption capacity, and development of strains at the beam-column joints were investigated. Furthermore, test results including tying and flexural resistances and rotation capacities of the composite joints were compared with design values from building codes and design guidelines. Performance of welded connections was also compared with pin connections tested by the authors previously. It was found that the applied load was sustained by flexural action before the bottom beam flange fractured from the joint and by catenary action after that. Design flexural resistance and rotation capacity of composite joints with moment-resisting connections could be achieved, but design values of tying resistance could not be achieved owing to partial damage of connections at the initial stage. However, tie force requirements from Eurocode 1 Part 1-7 could be met. (C) 2019 American Society of Civil Engineers.
机译:测试了五个具有焊接连接的复合接头中的一系列接头,研究了接头类型,平板厚度和抗剪栓钉数量的影响。包括带螺栓腹板的焊接无筋法兰和减小的梁截面连接。研究了梁柱节点的抗压机理,破坏模式,能量吸收能力以及应变的发展。此外,将包括结点和弯曲阻力以及复合材料接头的旋转能力在内的测试结果与建筑规范和设计指南中的设计值进行了比较。还将焊接连接的性能与先前作者测试过的插针连接进行了比较。结果发现,施加的载荷在底梁翼缘从接头处断裂之前通过挠曲作用而承受,并且在此之后通过悬链线作用而承受。具有抗弯连接的复合节点的设计抗弯强度和旋转能力可以实现,但由于初期连接的部分损坏,无法获得抗绑结的设计值。但是,可以满足欧洲规范1第1-7部分中的拉力要求。 (C)2019美国土木工程师学会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号