Postfabricated beams, that is, newly constructed beams in an existing structural system, provide an effective remedial solution to the serviceability and strength problems in an existing floor system and the discontinuities and irregularities in the seismic-force-resisting system of a structure, mostly caused by design and construction errors or intended omissions of certain members. The purpose of this study is to develop new techniques for postfabrication of these beams and connecting the postfabricated beams to the existing columns and slab. In this respect, an experimental study was planned and a total of 16half-scale specimens, including 3 monolithic (slab, columns, and beams cast monolithically) specimens and 13 specimens with postfabricated beams, were tested under monotonic vertical loads. The longitudinal reinforcement ratio of the postfabricated beam and the connection techniques of the postfabricated beam to the surrounding columns and slab constituted the test parameters. The tests indicated that the specimens with postfabricated beams were able to reach the strength and behavior of the monolithic specimens.
机译:预制梁,即现有结构系统中的新建梁,可以有效地解决现有楼板系统中的使用性和强度问题以及结构抗震力系统中的不连续性和不规则性(主要是由其引起的)由于设计和施工错误或某些成员的预期遗漏。这项研究的目的是开发新技术,以对这些梁进行后加工,并将后加工后的梁连接到现有的柱和平板上。在这方面,已计划进行一项实验研究,并在单调垂直载荷下测试了总共16个半比例试样,包括3个整体式(平板,圆柱和整体浇铸的梁)试样和13个带有预制梁的试样。预制梁的纵向配筋率以及预制梁与周围柱和平板的连接技术构成了测试参数。测试表明,带有预制梁的试样能够达到整体试样的强度和性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号