...
首页> 外文期刊>Journal of Strength and Conditioning Research >RELIABILITY OF PERFORMANCE MEASUREMENTS DERIVED FROM GROUND REACTION FORCE DATA DURING COUNTERMOVEMENT JUMP AND THE INFLUENCE OF SAMPLING FREQUENCY
【24h】

RELIABILITY OF PERFORMANCE MEASUREMENTS DERIVED FROM GROUND REACTION FORCE DATA DURING COUNTERMOVEMENT JUMP AND THE INFLUENCE OF SAMPLING FREQUENCY

机译:反跳过程中基于地面反应力数据得出的性能测量结果的可靠性及其对采样频率的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Force platforms are used extensively to measure force and power output during countermovement jump (CMJ). The purpose of this study was to examine measurement reliability and validity of commonly used performance measurements derived from ground reaction force (GRF)-time data during CMJ and the influence of sampling at different frequencies. Twenty-four men performed 2 trials of CMJ on a force platform, and GRF-time data were sampled at a rate of 500 Hz. Data obtained at 500 Hz were considered as the reference, and then data were resampled at 400, 250, 200, 100, 50, and 25 Hz, using interpolation. Commonly used power, force, and velocity performance measures were obtained from GRF-time data. Reliability was assessed by intraclass correlation coefficient (ICC) and coefficient of variation (CV) between the 2 trials within the session. Peak power, peak force, and peak velocity were highly reliable across all sampling frequencies (ICC = 0.92-0.98, CV = 1.3-4.1). Percentage differences from 500-Hz reference values ranged from -0.85 to 0.20% at 400 Hz, -1.88 to 0.89% at 250 Hz, - 1.80 to 1.31% at 200 Hz, -3.63 to 3.34% at 100 Hz, - 11.37 to 6.51 % at 50 Hz, and - 13.17 to 9.03% at 25 Hz. In conclusion, peak power, force, and velocity measurements derived from GRF to assess leg extensor capabilities are reliable within a test session except for peak rate of force development and time to peak power. With regard to sampling frequency, scientists and practitioners may consider sampling as low as 200 Hz, depending on the purpose of measurement, because the percentage difference is not markedly enlarged until the frequency is 100 Hz or lower. [PUBLICATION ABSTRACT]
机译:力平台广泛用于测量反向运动跳跃(CMJ)期间的力和动力输出。这项研究的目的是检验从CMJ期间地面反作用力(GRF)时间数据得出的常用性能测量的测量可靠性和有效性,以及不同频率下采样的影响。 24名男子在部队平台上进行了CMJ的2次试验,并以500 Hz的频率采样了GRF时间数据。将以500 Hz获得的数据视为参考,然后使用插值以400、250、200、100、50和25 Hz对数据进行重新采样。常用的功率,力和速度性能指标是从GRF时间数据获得的。通过组内两次试验之间的组内相关系数(ICC)和变异系数(CV)评估可靠性。在所有采样频率下,峰值功率,峰值力和峰值速度都非常可靠(ICC = 0.92-0.98,CV = 1.3-4.1)。与500Hz参考值的百分比差异在400Hz时为-0.85至0.20%,在250Hz时为-1.88至0.89%,在200Hz时为-1.80至1.31%,在100Hz为-3.63至3.34%,-11.37至6.51在50 Hz时为%,在25 Hz时为-13.17至9.03%。总之,从GRF得出的用于评估腿部伸肌能力的峰值功率,力量和速度测量在测试过程中是可靠的,除了峰值力量发展速度和达到峰值力量的时间。关于采样频率,科学家和从业人员可能会视测量目的而考虑低至200 Hz的采样,因为直到频率为100 Hz或更低时,百分比差异才会显着增大。 [出版物摘要]

著录项

  • 来源
    《Journal of Strength and Conditioning Research》 |2009年第3期|p.874-882|共9页
  • 作者单位

    NARUHIRO HOBI,3 ROBERT U. NEWTON,1 NAOKI KAWAMORI,1 MICHAEL R. MCGUIGAN,1 WILLIAM J. KRAEMER,1,2 AND KAZUNORI NOSAKA11 School of Exercise, Biomedical and Health Sciences, Edith Cowan University, Joondalup, Western Australia, Australia;

    2 Human Performance Laboratory, Department of Kinesiology, University of Connecticut, Storrs, Connecticut;

    and 3 Athletes and Coach Services, Western Australian Institute of Sport, Chremont, Western Australia, AustraliaAddress correspondence to Naruhiro Hori, ghori@wais.org.au23(3)/874-882Journal of Strength and Conditioning Research© 2009 National Strength and Conditioning Association;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号