Purpose The purpose of this research was to assess the precision and accuracy of a BCR and Tessier microwave-assisted sequential extraction procedure, in comparison to the conventional versions for a range of metals using a soil, lake and estuarine certified reference material (CRM). Materials and methods Four sequential extraction methods were run on the three different CRMs and the concentrations of Cu, Pb and Zn were analysed. Iron, Mn and Ca were also measured in each extract to determine the effect of the sequential extraction procedures on the sediment phases. Results and discussion Precision and accuracy of all four methods were very good and in line with values observed in the literature. The microwave-assisted sequential extraction procedures achieved results which were only broadly comparable to the conventional versions. Generally, the microwave procedures extracted lower concentrations of metals in the reducible phase, designed to attack the Fe and Mn oxides, and consequently the concentrations in the following fractions were higher. Conclusions The microwave-assisted procedures were faster than the conventional procedures and provided accurate and precise results. However, it is clear that the same fractions of sediment were not attacked by the microwave and conventional procedures, and therefore results from microwave analysis may not be comparable to conventional. However, these microwave procedures provide a fast, cost effective alternative to the conventional method for screening purposes. In order to provide comparable results, more method development is required.
机译:目的这项研究的目的是评估与使用土壤,湖泊和河口认证参考材料(CRM)的多种金属的常规版本相比,BCR和Tessier微波辅助顺序萃取程序的精度和准确性。材料和方法在三种不同的CRM上进行了四种顺序提取方法,并分析了Cu,Pb和Zn的浓度。还对每种提取物中的铁,锰和钙进行了测定,以确定顺序提取程序对沉积物相的影响。结果与讨论四种方法的精密度和准确性都非常好,与文献中观察到的值一致。微波辅助顺序提取程序所获得的结果仅与常规版本可比。通常,微波程序在可还原相中提取出较低浓度的金属,这些金属旨在侵蚀Fe和Mn氧化物,因此,以下馏分中的浓度较高。结论微波辅助程序比常规程序更快,并提供了准确而精确的结果。但是,很明显,相同比例的沉积物不会受到微波和常规程序的侵蚀,因此,微波分析的结果可能与常规方法不具有可比性。然而,这些微波程序为筛查目的提供了常规方法的快速,低成本的替代方法。为了提供可比的结果,需要更多的方法开发。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号