首页> 外文期刊>Journal of Radioanalytical and Nuclear Chemistry >Spectrophotometric determination of trace amount of uranium (VI) in different aqueous and organic streams of nuclear fuel processing using 2-(5-bromo-2-pyridylazo-5-diethylaminophenol)
【24h】

Spectrophotometric determination of trace amount of uranium (VI) in different aqueous and organic streams of nuclear fuel processing using 2-(5-bromo-2-pyridylazo-5-diethylaminophenol)

机译:使用2-(5-溴-2-吡啶基偶氮-5-二乙基氨基苯酚)分光光度法测定核燃料加工中不同水和有机物流中的痕量铀(VI)

获取原文
获取原文并翻译 | 示例
       

摘要

Present investigation describes the development of a spectrophotometric method for trace level determination of U(VI) encountered during the process of nuclear fuel fabrication and reprocessing industries. A chromogenic reagent, 2-(5-bromo-2-pyridylazo-5-diethylaminophenol) (Br–PADAP) is used to complex with U(VI) under optimized solution conditions. The absoption maxima of the uranyl Br–PADAP complex at 578 nm is computed to be 73540 ± 1438 for U–Br–PADAP solution containing 20% ethanol (in aqueous sample media) and 58216 ± 1208 for U–Br–PADAP solution containing 80% ethanol (for organic sample media). Employing suitable sample treatment methods, the scope of analytical method has been widened to permit accurate determination of U(VI) in the samples with variation in the relative compositions of Th(IV), Pu(IV) and Fe(III). The method is applicable to samples matrices with, acidic, alkaline highly salted media. Effect of commonly associated ionic species on the optical density of U–Br–PADAP is determined. Depending on the extent of the interfering impurities present, the method permits estimation of U(VI) either direct or after its selective extraction into tri-octyl phosphine oxide dissolved in cyclohexane. The method is precise with <5% standard error and can be used for the estimation of uranium in organic as well as in aqueous samples. The method has been validated for quantitative determination of uranium extracted in the organic phase comprising of heavy metal extractants like TBP, HDEHP, PC-88A and Aliquot 336.
机译:目前的研究描述了一种用于在核燃料制造和后处理行业过程中遇到的痕量U(VI)含量测定的分光光度法的开发。发色试剂2-(5-溴-2-吡啶基偶氮-5-二乙基氨基苯酚)(Br-PADAP)用于在最佳溶液条件下与U(VI)络合。对于含20%乙醇的U–Br–PADAP溶液,在578 nm处,铀基Br–PADAP络合物的最大吸收吸光度计算为73540±1438,对于含有80%的U–Br–PADAP溶液,其吸光度最大值为73540±1438。 %乙醇(用于有机样品介质)。通过使用合适的样品处理方法,分析方法的范围已经扩大,可以准确测定样品中的U(VI),而Th(IV),Pu(IV)和Fe(III)的相对组成也有所不同。该方法适用于带有酸性,碱性高盐分介质的样品基质。确定了通常相关的离子种类对U–Br–PADAP的光密度的影响。根据存在的干扰杂质的程度,该方法可以直接或在将U(VI)选择性萃取到溶于环己烷的三辛基氧化膦中后进行估算。该方法精确度低于标准误差5%,可用于估算有机样品和水性样品中的铀。该方法已经过验证,可用于定量测定有机相中萃取的铀,该有机相包含重金属萃取剂,如TBP,HDEHP,PC-88A和等分336。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号