首页> 外文期刊>Journal of Neuro-Oncology >Intracranial application of IMRT based radiosurgery to treat multiple or large irregular lesions and verification of infra-red frameless localization system
【24h】

Intracranial application of IMRT based radiosurgery to treat multiple or large irregular lesions and verification of infra-red frameless localization system

机译:基于IMRT的放射外科手术在颅内的应用,用于治疗多发或大的不规则病变以及红外无框定位系统的验证

获取原文
获取原文并翻译 | 示例
           

摘要

We have employed a frameless localization system for intracranial radiosurgery, utilizing a custom biteblock with fiducial markers and an infra-red camera for set-up and monitoring patient position. For multiple brain metastases or large irregular lesions, we use a single-isocenter intensity-modulated approach. We report our quality assurance measurements and our experience using Intensity Modulated Radiosurgery (IMRS) to treat such intracranial lesions. A phantom with integrated targets and fiducial markers was utilized to test the positional accuracy of the system. The frameless localization system was used for patient setup and target localization as well as for motion monitoring during treatment. Inverse optimization planning gave satisfactory dose coverage and critical organ sparing. Patient setup was guided by the infrared camera through fine adjustment in three translational and three rotational degrees for isocenter localization and verified by orthogonal kilovoltage (kV) images, taken before treatment to ensure the accuracy of treatment. The relative localization of the camera based system was verified to be highly accurate along three translational directions of couch motion and couch rotation. After verification, we began treating patients with this technique. About 8–12 properly selected fixed beams with a single isocenter were sufficient to achieve good dose coverage and organ sparing. Portal dosimetry with an Electronic Portal Imaging Device (EPID) and kV images provided excellent quality assurance for the IMRS plan and patient setup. The treatment time was less than 60 min to deliver doses of 16–20 Gy in a single fraction. The camera-based system was verified for positional accuracy and was deemed sufficiently accurate for stereotactic treatments. Single isocenter IMRS treatment of multiple brain metastases or large irregular lesions can be done within an acceptable treatment time and gives the benefits of dose-conformity and organ-sparing, easy plan QA, and patient setup verification. Keywords Frameless - Radiosurgery - Intensity modulated - Infra-red
机译:我们已经为颅内放射外科手术采用了无框架定位系统,该系统使用了带有基准标记的定制咬合块和红外摄像头来设置和监视患者位置。对于多发性脑转移或大的不规则病变,我们使用单等中心强度调制方法。我们报告了我们的质量保证措施和使用调强放射外科手术(IMRS)治疗此类颅内病变的经验。具有集成目标和基准标记的模型用于测试系统的位置精度。无框架定位系统用于患者设置和目标定位以及治疗过程中的运动监控。逆向优化计划给出了令人满意的剂量覆盖范围和关键器官保留。红外摄像机通过在三个平移和三个旋转角度上进行微调以进行等中心点定位来指导患者设置,并通过正交千伏(kV)图像进行验证,以确保治疗的准确性。经验证,基于摄像头的系统的相对定位在沙发运动和沙发旋转的三个平移方向上非常准确。经过验证后,我们开始使用这种技术治疗患者。适当选择的大约8–12个具有单个等中心点的固定光束足以实现良好的剂量覆盖范围和节省器官。带有电子门禁成像设备(EPID)的门禁剂量和kV图像为IMRS计划和患者设置提供了出色的质量保证。治疗时间少于60分钟,可以一次递送16-20 Gy的剂量。基于摄像头的系统经过了位置精度验证,被认为对于立体定向治疗足够准确。可以在可接受的治疗时间内对多个脑转移瘤或大的不规则病变进行单等中心IMRS治疗,并具有剂量符合性和器官保存,易于计划的质量保证和患者设置验证的优势。无框-放射外科-强度调制-红外

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号