首页> 外文期刊>Journal of Membrane Science >Diffusion coefficients of aromatic sin nonporous PEBA membranes
【24h】

Diffusion coefficients of aromatic sin nonporous PEBA membranes

机译:芳香性无孔PEBA膜的扩散系数

获取原文
获取原文并翻译 | 示例
       

摘要

diffusion coefficients of the aromatic compounds phenol aniline, 2-chlorophenol, 4-nitrophenol, 2,4-dinitrophenol, 4'4- isopropylidenediphenol (Bisphenol A) pyridine in dense polyether-polyamide block-copolymer (PEBA) 4033-PE and PEBA 4033 membranes have been measured using the technique of the time-dependent dialysis in dilute aqueous solution. A new evaluation procedure is presented which allows to determine diffusion coefficients in case of an nonstationary dialysis Process. Diffusion coefficients obtained at 298.15 and 323.15 K are used to determine the so called activation energy of Diffusion. The data are obtained in membranes used under realistic conditions of pervaporation or reverse osmosis where the Polymer membrane is saturated to ca.1/100 with water. The method is generally useful for estimating parameters of membrane Separation processes in a quantitative way based on the solution diffusion model.
机译:芳族化合物苯酚苯胺,2-氯苯酚,4-硝基苯酚,2,4-二硝基苯酚,4'4-异丙基二烯二酚(双酚A)吡啶在致密聚醚-聚酰胺嵌段共聚物(PEBA)4033-PE和PEBA 4033中的扩散系数已经在稀水溶液中使用时间依赖性透析技术对膜进行了测量。提出了一种新的评估程序,该程序可以确定非平稳透析过程中的扩散系数。在298.15和323.15 K处获得的扩散系数用于确定所谓的扩散活化能。数据是在实际的全蒸发或反渗透条件下使用的膜中获得的,在该条件下,聚合物膜用水饱和到大约1/100。该方法通常可用于基于溶液扩散模型以定量方式估计膜分离过程的参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号