首页> 外文期刊>Journal of Mechanical Science and Technology >Measurements of air temperature distribution and optimum cooling condition inside the computer system
【24h】

Measurements of air temperature distribution and optimum cooling condition inside the computer system

机译:测量计算机系统内部的空气温度分布和最佳冷却条件

获取原文
获取原文并翻译 | 示例
           

摘要

Measurements of the temperature distributions of the cooling air flow inside a computer system have been made. An investigation of the optimum cooling condition for the computer system has also been made. Seventy-one K-type (Chromega-Alumega) thermocouples were used to measure distributions of the air flow temperature inside the computer system. They were calibrated against the standard platinum resistance thermometer (PRT) in a constant water circulating bath within an accuracy of ± 0.15 °C. It was found that the number and position of cooling fans as well as their operating condition, whether air intake or air discharge, can greatly influence the cooling effectiveness in the computer system. The results show that the flow rate of intake air should not be higher than that of the discharge air for the most effective cooling. It follows that the optimum cooling has been achieved inside the computer when the three fans are positioned in the inlet front, outlet back, and outlet top in the computer, respectively. Under these conditions, not only is the average temperature inside the computer system maintained at an appropriate level, but the most effective cooling around the central processor (CPU) and graphic card which are responsible for the largest amount of heat dissipation can be accomplished.
机译:已经对计算机系统内部的冷却气流的温度分布进行了测量。还对计算机系统的最佳冷却条件进行了研究。七十一个K型(Chromega-Alumega)热电偶用于测量计算机系统内部气流温度的分布。在标准的铂电阻温度计(PRT)的恒定水循环浴中对它们进行了校准,精度为±0.15°C。已经发现,冷却风扇的数量和位置以及它们的运行状况(无论是进气还是排气)都会极大地影响计算机系统的冷却效率。结果表明,为了最有效地冷却,进气的流速不应高于排气的流速。因此,当三个风扇分别位于计算机的入口前部,出口后部和出口顶部时,已在计算机内部实现了最佳冷却效果。在这些条件下,不仅可以将计算机系统内部的平均温度维持在适当的水平,而且可以实现负责最大散热量的中央处理器(CPU)和图形卡周围的最有效散热。

著录项

  • 来源
    《Journal of Mechanical Science and Technology》 |2009年第2期|544-549|共6页
  • 作者单位

    School of Mechanical and Automotive Engineering High Safety Vehicle Core Technology Research Center Inje University 607 Obang-dong Gimhae Gyeongnam 621-749 Korea;

    Graduate School Department of Mechanical Engineering Inje University 607 Obang-dong Gimhae Gyeongnam 621-749 Korea;

    Graduate School Department of Mechanical Engineering Inje University 607 Obang-dong Gimhae Gyeongnam 621-749 Korea;

    Graduate School Department of Mechanical Engineering Inje University 607 Obang-dong Gimhae Gyeongnam 621-749 Korea;

    Graduate School Department of Mechanical Engineering Inje University 607 Obang-dong Gimhae Gyeongnam 621-749 Korea;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Computer system; Air flow; Temperature distribution; Cooling fan; Optimum cooling condition;

    机译:计算机系统;气流;温度分布;冷却风扇;最佳冷却条件;