首页> 外文期刊>Journal of Low Temperature Physics >Vibrating Wire Thermometry in Superfluid 3He
【24h】

Vibrating Wire Thermometry in Superfluid 3He

机译:超流体3He中的振弦式测温

获取原文
获取原文并翻译 | 示例
           

摘要

We report systematic measurements of the response of a Vibrating Wire Resonator (VWR) in normal and superfluid liquid 3He. Special attention has been paid to the hydrodynamic regime of the superfluid B-phase, where the response parameters of the VWR do not follow a simple law. We show that a simple interpolation between the region where first order slip-corrections can be applied and the ballistic regime is insufficient. Measuring an empirical effective viscosity, we propose a temperature calibration method which allows the use of VWRs as a secondary thermometer at intermediate and high pressures in the temperature range 0.2 T c < T < 50 mK.
机译:我们报告了振弦共振器(VWR)在正常和超流体3He中的响应的系统测量。已经特别注意了超流体B相的流体力学状态,其中VWR的响应参数不遵循简单的定律。我们表明,在可以应用一阶滑移校正的区域与弹道之间的简单插值是不够的。通过测量经验有效粘度,我们提出了一种温度校准方法,该方法允许在0.2 T c

著录项

  • 来源
    《Journal of Low Temperature Physics》 |2004年第2期|3-14|共12页
  • 作者单位

    Centre de Recherches sur les Très Basses Températures;

    Centre de Recherches sur les Très Basses Températures;

    Centre de Recherches sur les Très Basses Températures;

    Centre de Recherches sur les Très Basses Températures;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号