A new microwave photonic system for determining the angle of arrival (AOA) of a continuous wave (CW) or pulsed microwave signal is presented. It is based on a dual-polarisation dual-drive Mach-Zehnder modulator followed by an optical notch filter for carrier suppression. Two orthogonal-polarised carrier- suppressed optical signals are detected by low-frequency photodetectors that generate two DC voltages. An incoming microwave signal AOA can be obtained from the ratio of the two DC voltages, without the need of a calibration procedure or measuring the incoming microwave signal power level, which are required in previously reported structures. The proposal system can be incorporated with a conventional radar receiver front end consists of mixers and filters, for measuring the AOA of a pulsed microwave signal. Experimental results demonstrate 0 degrees-63 degrees AOA measurement with less than 2 degrees errors for an input microwave signal having different frequencies and different power levels.
机译:提供了一种用于确定连续波(CW)或脉冲微波信号的到达角(AOA)的新微波光子系统。它基于双偏振双驱动Mach-Zehnder调制器,然后是用于载波抑制的光学槽滤波器。通过产生两个直流电压的低频光电探测器检测两个正交偏振的载波抑制光信号。可以从两个DC电压的比率获得输入的微波信号AOA,而不需要校准程序或测量进入的微波信号功率水平,这在先前报告的结构中是所需的。该提案系统可以与传统的雷达接收器前端结合,包括混合器和过滤器,用于测量脉冲微波信号的AOA。实验结果表明,对于具有不同频率和不同功率水平的输入微波信号,具有小于2度误差的0度-63度AOA测量。