首页> 外文期刊>Journal of Heat Transfer >Experimental Investigation On The Heat Transfer Between A Heated Microcantilever And A Substrate
【24h】

Experimental Investigation On The Heat Transfer Between A Heated Microcantilever And A Substrate

机译:微悬臂梁与基体之间传热的实验研究

获取原文
获取原文并翻译 | 示例
       

摘要

This work describes the heat transfer process from a heated microcantilever to a substrate. A platinum-resistance thermometer with a 140 nm width was fabricated on a SiO_2-coated silicon substrate. The temperature coefficient of resistance estimated from the measurement was 7 × 10~(-4) K~(-1), about one-fifth of the bulk value of platinum. The temperature distribution on the substrate was obtained from the thermometer reading, as the cantilever raster scanned the substrate. Comparison between the measurement and calculation reveals that up to 75% of the cantilever power is directly transferred to the substrate through the air gap. From the force-displacement experiment, the effective tip-specimen contact thermal conductance was estimated, to be around 40 n W/K. The findings from this study should help understand the thermal interaction between the heated cantilever and the substrate, which is essential to many nanoscale technologies using heated cantilevers.
机译:这项工作描述了从加热的微悬臂梁到基板的传热过程。在涂有SiO_2的硅基板上制作了一个140纳米宽的铂电阻温度计。通过测量估算出的电阻温度系数为7×10〜(-4)K〜(-1),约为铂体积值的五分之一。当悬臂光栅扫描基板时,可从温度计读数获得基板上的温度分布。测量和计算之间的比较表明,高达75%的悬臂功率通过气隙直接转移到基板上。根据力位移实验,有效的尖端样品接触热导估计为40 n W / K。这项研究的发现应有助于理解加热的悬臂与基板之间的热相互作用,这对于许多使用加热的悬臂的纳米技术至关重要。