首页> 外文期刊>The journal of hazmat transportation >DROP TEST REQUIREMENTS FOR TYPE A PACKAGES
【24h】

DROP TEST REQUIREMENTS FOR TYPE A PACKAGES

机译:A型包装的滴液测试要求

获取原文
获取原文并翻译 | 示例
       

摘要

A customer of Robatel Technologies inquired about shipping a type A package without an upper impact limiter. Further it was asked if the drop test requirements for Type A packages would hold for this configuration. Specifically, would it be necessary to drop test in every orientation if that orientation was not incident to "normal" transportation but would only occur in an accident situation. The package in question is massive (roughly 7 feet around and 14 feet high) and only one is attached when hauled on a 45-foot flatbed. Dropping this whole configuration the 0.3 m required of a package this size (>15,000 kg) is a challenge. The full interpretation has pictures of the configuration. IAEA referenced this situation in SSG-26 §722.6 in which the difficulty of performing the drop test in all possible orientations for large and complex packages is recognized. The IAEA suggests that designs requiring approval of the Competent Authority should be tested in the most damaging orientation regardless of package size or aspect ratio.
机译:Robatel Technologies的一位客户询问是否要运送没有上限冲击限制器的A型包装。进一步询问是否对这种配置适用于Type A封装的跌落测试要求。具体而言,如果该定向不是偶然发生在“正常”运输中,而是仅在事故情况下发生,则有必要在每个定向上都进行掉落测试。所讨论的包裹很大(大约7英尺高,14英尺高),拖曳在45英尺的平板上时只能装一个。将这种整体结构的重量降低到大于0.3千克(> 15,000千克)的包装所要求的0.3 m是一个挑战。完整解释包括配置图片。原子能机构在SSG-26§722.6中提到了这种情况,在这种情况下,对于大型和复杂的包装,难以在所有可能的方向进行跌落试验。 IAEA建议,无论包装尺寸或长宽比如何,都应在最具破坏性的方向上测试需要获得主管当局批准的外观设计。

著录项

  • 来源
    《The journal of hazmat transportation》 |2020年第6期|14-14|共1页
  • 作者

  • 作者单位
  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 05:23:59

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com