A coprecipitation procedure has been presented prior to flame atomic absorption spectrometric determi-nation of nickel, cadmium and lead ions in environmental samples. Analyte ions were coprecipitated by using copper hydroxide precipitate. The influences of some analytical parameters like amounts of copper, sample volume, etc., on the recoveries of the analytes were investigated. The interference of other ions was negligible. Under the optimized conditions, the detection limits (3 sigma, n = 15)of lead(II), nickel(II)and cadmium(II) were 7.0,3.0 and 2.0 μg/L, respectively. The proposed method has been successfully applied for the determination of traces of Ni, Cd and Pb in environmental samples like tap water.
机译:在火焰原子吸收光谱法测定环境样品中的镍,镉和铅离子之前,已经提出了一种共沉淀程序。通过使用氢氧化铜沉淀使分析物离子共沉淀。研究了一些分析参数(如铜量,样品量等)对分析物回收率的影响。其他离子的干扰可以忽略不计。在最佳条件下,铅(II),镍(II)和镉(II)的检出限(3σ,n = 15)分别为7.0、3.0和2.0μg/ L。该方法已成功应用于环境水样(如自来水)中痕量镍,镉和铅的测定。