...
首页> 外文期刊>Journal of Hazardous Materials >Investigation of the effect of different electrodes and their connections on the removal efficiency of 4-nitrophenol from aqueous solution by electrocoagulation
【24h】

Investigation of the effect of different electrodes and their connections on the removal efficiency of 4-nitrophenol from aqueous solution by electrocoagulation

机译:不同电极及其连接对电凝去除水溶液中4-硝基苯酚的影响的研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This study investigates the influence of variables on the removal efficiency of solution containing 4-NP (4-nitrophenol) by D. C. electrocoagulation (EC). The efficiency of different electrode connections and materials (steel 310, Fe, Al, graphite and steel 304) for 4-NP removal is compared. Current density, time of electrolysis, interelectrode distance, supporting electrolyte concentration and stirring rate of the solution were the variables that mostly influenced the 4-NP removal. Initially, a simple electrochemical cell was prepared with an anode and a cathode. Then the effect of each variable was studied separately using aqueous 4-NP in a batch mode. For a solution of 20 mg/L 4-NP + 300 mg/L NaCl with chemical oxygen demand (COD) of approximately 40 mg O_2/L, almost up to 99% 4-NP and 65% COD were removed, when the pH was about 9, time of electrolysis was approximately 10min, current density was 100 Am~(-2), interelctrode distance was 15mm and stirring rate was 400 rpm. In the second series of experiments, the efficiency of EC cells with monopolar electrodes in series and parallel connections and an EC cell with bipolar electrodes was compared with that of a simple electrochemical cell. The best results obtained when steel 310 and Fe are used as anodes and employing Al and graphite as anodes would not be satisfactory. Also findings show that the types of sacrificial electrodes are not very significant in the removal of 4-NP. In the real wastewater obtained from Tabriz petrochemical plant 52% removal could be achieved after 10min with using steel 310 as anode and steel 304 as cathode.
机译:这项研究调查变量对D.C.电凝(EC)去除含有4-NP(4-硝基苯酚)溶液的效率的影响。比较了不同电极连接和材料(钢310,铁,铝,石墨和钢304)去除4-NP的效率。电流密度,电解时间,电极间距离,支持电解质浓度和溶液的搅拌速率是主要影响4-NP去除的变量。最初,用阳极和阴极制备简单的电化学电池。然后使用批处理模式分别使用4-NP水溶液研究每个变量的效果。对于20 mg / L 4-NP + 300 mg / L NaCl且化学需氧量(COD)约为40 mg O_2 / L的溶液,当pH值达到时,几乎除去了高达99%的4-NP和65%的COD。电解时间约为9,电解时间约为10分钟,电流密度为100 Am〜(-2),电极间距离为15mm,搅拌速度为400 rpm。在第二系列实验中,将具有串联和并联连接的单极电极的EC电池和具有双极电极的EC电池的效率与简单的电化学电池进行了比较。当将钢310和Fe用作阳极并将Al和石墨用作阳极时,获得的最佳结果将不令人满意。还发现,牺牲电极的类型在去除4-NP方面不是很重要。在使用大不里士石化厂生产的真实废水中,使用钢310作为阳极,钢304作为阴极,在10分钟后可以实现52%的去除率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号