In the present study, the treatability of a metal plating wastewater containing complexed metals originating from the nickel and zinc plating process by electrocoagulation using stainless steel electrodes was experimentally investigated. The study focused on the effect of important operation parameters on electrocoagulation process performance in terms of organic complex former, nickel and zinc removals as well as sludge production and specific energy consumption. The results indicated that increasing the applied current density from 2.25 to 9.0 mA/cm~2 appreciably enhanced TOC removal efficiency from 20% to 66%, but a further increase in the applied current density to 56.25 mA/cm~2 did not accelerate TOC removal rates. Electrolyte concentration did not affect the process performance significantly and the highest TOC reduction (66%) accompanied with complete heavy metal removals were achieved at the original chloride content (≈1500 mg Cl/L) of the wastewater sample. Nickel removal performance was adversely affected by the decrease of initial pH from its original value of 6. Optimum working conditions for electrocoagulation of metal plating effluent were established as follows: an applied current density of 9 mA/cm~2, the effluent's original electrolyte concentration and pH of the composite sample. TOC removal rates obtained for all electrocoagulation runs fitted pseudo-first-order kinetics very well (R~2 > 92-99).
机译:在本研究中,通过使用不锈钢电极的电凝法,对含镍和锌电镀过程中产生的复杂金属的金属电镀废水的可处理性进行了实验研究。该研究集中在重要的操作参数对电凝过程性能的影响方面,包括有机络合物形成剂,镍和锌的去除以及污泥的产生和比能耗。结果表明,将施加电流密度从2.25提高到9.0 mA / cm〜2可以将TOC去除效率从20%显着提高到66%,但是将施加电流密度进一步提高到56.25 mA / cm〜2并不能加速TOC。去除率。电解液浓度不会显着影响工艺性能,在废水样品的原始氯化物含量(约1500 mg Cl / L)下,TOC降低最高(66%),同时重金属完全去除。镍的去除性能受到初始pH值从其原始值6降低的不利影响。确定金属电镀废水的电凝最佳工作条件如下:施加的电流密度为9 mA / cm〜2,即废水的原始电解质浓度和复合样品的pH。所有电凝运行获得的TOC去除率非常符合拟一级动力学(R〜2> 92-99)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号