A spiral heat exchanger (SHE) constructed of Grade 316L stainless steel developed a leak after 8 years of service as a condenser on a distillation tower. Examination of the SHE identified the leak as being located on the cooling water side in the heat affected zone (HAZ) of a weld joining two plates. Cooling water deposits were observed in a V-shaped corner formed by the weld. A metallurgical examination identified the presence of transgranular cracks at the HAZ on the cooling water side. Analysis of the cooling water revealed the presence of chlorides. Based on the metallurgical analysis and the presence of chlorides, it was determined that the cracks and resulting leak were the result of chloride stress corrosion cracking.
机译:由316L不锈钢制成的螺旋式热交换器(SHE)在用作蒸馏塔的冷凝器8年后出现泄漏。对SHE的检查发现泄漏位于连接两个板的焊缝的热影响区(HAZ)的冷却水侧。在焊缝形成的V形拐角处观察到冷却水沉积。冶金检查确定了冷却水一侧的热影响区存在晶间裂纹。对冷却水的分析表明存在氯化物。根据冶金分析和氯化物的存在,确定裂纹和由此产生的泄漏是氯化物应力腐蚀开裂的结果。