Hole-surface charged body potential (CBP) measurements were taken over a 173-day period during a drip-injection, tracer experiment in partially saturated, fractured basalt. A continuous, enhanced conductivity, potassium chloride (KCl) solution was dripped into the fractured basalt and energized directly through a current electrode placed in the conductive solution. The constant concentration, KCl solution was introduced above a perched water table at an average rate of 10.07 L/day under a constant hydraulic head for 76 days. The KCl drip period was followed by a 34-day tap water drip period and a 62-day drainage period. Hole-surface CBP measurements were taken over time to delineate the evolution of the asymmetrical, vadose zone, plume. A 15 by 15 grid of land surface based, porous pot electrodes (copper sulfate), located symmetrically about the centrally located injection borehole, was used for the hole-surface CBP experiment. Ratios of electrical potentials measured at the land surface over time were contoured and profiled to delineate the evolution of the electrolyte plume.
机译:孔表面带电体电势(CBP)测量是在部分饱和,破裂的玄武岩中进行的滴注示踪剂实验中进行的173天。将连续的,增强电导率的氯化钾(KCl)溶液滴入破裂的玄武岩中,并通过放置在导电溶液中的电流电极直接通电。将恒定浓度的KCl溶液在恒定水压下以10.07 L /天的平均速率引入栖息的地下水位上方76天。 KCl滴水期之后是34天的自来水滴水期和62天的排水期。随时间进行孔表面CBP测量,以描绘不对称渗流带羽状流的演变。围绕中心注入井孔对称放置的15×15网格的陆基多孔罐电极(硫酸铜)用于孔表面CBP实验。轮廓和轮廓化在陆地表面随时间测量的电势比率,以描绘电解质羽流的演变。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号