首页> 外文期刊>Journal of Environmental Management >A full-scale comparison of two hybrid constructed wetlands treating domestic wastewater in Pakistan
【24h】

A full-scale comparison of two hybrid constructed wetlands treating domestic wastewater in Pakistan

机译:巴基斯坦两个混合人工湿地处理生活污水的全面比较

获取原文
获取原文并翻译 | 示例
       

摘要

Objective of the current work was to monitor the year-round response of full-scale hybrid constructed-wetlands (CWs) treating domestic wastewater under variable continuous flow. Two systems were evaluated: system-I consisted of an anaerobic baffled reactor (ABR) followed by a saturated vertical subsurface-flow (VSSF) CW and a free-water-surface (FWS) CW as a tertiary treatment; system-Ⅱ consisted of an ABR followed by a horizontal subsurface-flow (HSSF) CW and FWS. Maximum reduction of 80 and 78%, 81 and 82%, 63 and 69%, 79 and 89% for chemical oxygen demand (COD), biological oxygen demand (BOD), total kjeldahl nitrogen (TKN) and total suspended solids (TSS) was achieved in Systems I and II respectively. There was also effective removal (94% and 93%) of the bacterial population in both systems while more than 94% of pathogenic microorganisms were removed. Data from both systems were further used to compute the first-order rate constants for the k-C* model commonly used in CW design. The treatment performance was confirmed to follow a first-order reaction rate, in which the k_(20) values of chemical oxygen demand (COD), biological oxygen demand (BOD), total kjeldahl nitrogen (TKN), total phosphorus (TP) and total suspended solids were calculated as 165, 117, 133, 7.5 and 78myr~(-1) respectively for VSSF and 226,134, 199, 22 and 73 m yr~(-1) respectively for HSSF. A positive correlation with temperature was discovered for all parameters in both systems.
机译:当前工作的目标是监测可变连续流量下全尺寸混合人工湿地(CW)全年处理生活污水的响应。评估了两个系统:系统I由厌氧折流板反应器(ABR)和随后的饱和垂直地下流(VSSF)CW和自由水表面(FWS)CW组成,进行三次处理;系统Ⅱ由一个ABR,一个水平地下流(CSF)和FWS组成。化学需氧量(COD),生物需氧量(BOD),凯氏总氮(TKN)和总悬浮固体(TSS)的最大减少量分别为80%和78%,81%和82%,63%和69%,79%和89%分别在系统I和II中实现。在两个系统中,细菌种群也都得到了有效清除(94%和93%),而超过94%的病原微生物被清除了。来自两个系统的数据被进一步用于计算CW设计中常用的k-C *模型的一阶速率常数。证实处理性能遵循一阶反应速率,其中化学需氧量(COD),生物需氧量(BOD),总凯氏氮(TKN),总磷(TP)和VSSF的总悬浮固体分别为165、117、133、7.5和78myr〜(-1),HSSF分别为226,134、199、22和73 m yr〜(-1)。发现两个系统中所有参数的温度均呈正相关。

著录项

  • 来源
    《Journal of Environmental Management》 |2018年第15期|349-358|共10页
  • 作者单位

    Department of Microbiology, Quaid-i-Azam University, 45320 Islamabad, Pakistan,Department of Industrial Biological Sciences, Ghent University Campus Kortrijk, Graaf Karel de Coedelaan 5, 8500 Kortrijk, Belgium;

    Department of Industrial Biological Sciences, Ghent University Campus Kortrijk, Graaf Karel de Coedelaan 5, 8500 Kortrijk, Belgium;

    Department of Microbiology, Quaid-i-Azam University, 45320 Islamabad, Pakistan;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Anaerobic baffled reactor; Constructed wetlands; k-C* model; Wastewater treatment; Reuse;

    机译:厌氧折流板反应器;人工湿地;k-C *模型;废水处理;重用;