Short-term repeatability of joint space width measurements using a magnetic resonance imaging compatible knee positioning device

机译:使用磁共振成像兼容膝盖定位设备进行关节间隙宽度测量的短期可重复性

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to evaluate a magnetic resonance imaging (MRI) compatible knee positioning device to aid in minimizing intratechnologist and intertechnologist differences of minimum joint space width (JSW) measurements. Five subjects were scanned by two separate technologists, with and without an MRI-compatible positioning device. A semi-automated program calculated the minimum JSW of the tibiofemoral and patellofemoral joints. The scan-to-scan repeatability was evaluated from measurements between serial scans without subject repositioning, and the intratechnologist and intertechnologist repeatabilities were evaluated when the subject was removed from the magnet and repositioned by an individual technologist. The root mean square (RMS) error of the JSW measurements was also calculated. All measures of scan-to-scan repeatability and intratechnologist repeatability were unchanged with the MRI-compatible positioning device. The intertechnologist repeatability decreased from 0.70 to 0.42 mm, and the RMS error was significantly reduced (P = 0.0006) from 0.26 to 0.15 mm for the tibiofemoral joint. The variability of patellofemoral JSW measurements increased when using the positioning device; however, the increases were not statistically significant. The intertechnologist repeatability increased from 1.55 to 1.79 mm, and the RMS error increased from 0.58 to 0.73 mm. The MRI-compatible positioning device was successful at reducing JSW measurement variability at the tibiofemoral joint. The increase in measurement variability at the patellofemoral joint may be due to local incongruities of the articular surfaces. An MRI-compatible positioning device may be beneficial for quantitative longitudinal studies evaluating knee joint health.
机译:这项研究的目的是评估兼容磁共振成像(MRI)的膝盖定位设备,以帮助最小化技术人员和技术人员之间最小关节间隙宽度(JSW)测量的差异。两名受试者分别在有和没有MRI兼容定位设备的情况下对五名受试者进行了扫描。半自动化程序计算了胫股和pa股关节的最小JSW。从连续扫描之间的测量中评估了每次扫描的可重复性,而无需重新放置对象;当从磁体中取出对象并由单个技术人员重新放置对象时,将评估技术人员和技术人员之间的重复性。还计算了JSW测量的均方根(RMS)误差。使用MRI兼容的定位设备,所有扫描重复性和技术人员重复性的所有度量均保持不变。对于胫股关节,技术人员的可重复性从0.70降低到0.42 mm,RMS误差从0.26降低到0.15 mm(P = 0.0006)显着降低。使用定位装置时,tell股JSW测量值的变异性增加;但是,增加幅度没有统计学意义。技术人员的可重复性从1.55毫米增加到1.79毫米,RMS误差从0.58毫米增加到0.73毫米。 MRI兼容的定位设备成功地减少了胫股关节的JSW测量变异性。 em股关节处测量变异性的增加可能是由于关节表面局部不一致所致。 MRI兼容的定位设备可能有助于定量纵向研究评估膝关节健康。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号