首页> 外文期刊>Journal of Energy Resources Technology >Evaluation of Electricity Generation From Underground Coal Fires and Waste Banks
【24h】

Evaluation of Electricity Generation From Underground Coal Fires and Waste Banks

机译:地下燃煤和废物库发电的评估

获取原文
获取原文并翻译 | 示例
       

摘要

A temperature response factors model of vertical thermal energy extraction boreholes is presented to evaluate electricity generation from underground coal fires and waste banks. Sensitivity and life-cycle cost analyses are conducted to assess the impact of system parameters on the production of 1 MW of electrical power using a theoretical binary-cycle power plant. Sensitivity analyses indicate that the average underground temperature has the greatest impact on the exiting fluid temperatures from the ground followed by fluid flow rate and ground thermal conductivity. System simulations show that a binary-cycle power plant may be economically feasible at ground temperatures as low as 190℃.
机译:建立了垂直热能开采井眼的温度响应因子模型,以评估地下燃煤和废物库的发电量。进行了敏感性和生命周期成本分析,以评估系统参数对使用理论上的二元循环发电厂产生的1 MW电力的影响。敏感性分析表明,地下平均温度对从地面排出的流体温度的影响最大,其次是流体流速和地面热导率。系统仿真表明,在地面温度低至190℃时,二元循环发电厂在经济上是可行的。