Seismic Response of Base-Isolated Benchmark Building with Variable Sliding Isolators

机译:可变滑动隔离器的基础隔震基准建筑物的地震响应

获取原文
获取原文并翻译 | 示例
       

摘要

The seismic response of base-isolated benchmark building with variable sliding isolators like variable friction pendulum system (VFPS), variable frequency pendulum isolator (VFPI), and variable curvature friction pendulum system (VCFPS), along with conventional friction pendulum system (FPS), was studied under the seven earthquakes. The earthquakes are applied bi-directionally in the horizontal plane ignoring vertical ground motion component. The shear type base-isolated benchmark building is modeled as three-dimensional linear elastic structure having three degrees of freedom at each floor level. Time domain dynamic analysis of the benchmark building was carried out with the help of constant average acceleration Newmark-Beta method and nonlinear isolation forces was taken care by fourth-order Runge-Kutta method. The base-isolated benchmark building is investigated for uniform isolation and hybrid isolation in combination with laminated rubber bearings through the performance criteria and lime history response of important structural response parameters like floor accelerations, base displacement, etc. It is observed that variable sliding isolators performed better than conventional FPS due to their varying characteristic properties which enable them to alter the isolator forces depending upon their isolator displacements thus improves the performance of the structure. The VFPS efficiently controls large isolator displacements and VFPI and VCFPS improve super structural response on the cost of isolator displacement. It is also observed that the hybrid isolation is relatively better in comparison to the uniform isolation for the benchmark building.
机译:具有可变滑动隔离器(如可变摩擦摆系统(VFPS),可变频率摆隔离器(VFPI)和可变曲率摩擦摆系统(VCFPS))以及常规摩擦摆系统(FPS)的基础隔震基准建筑物的地震响应,在七次地震下进行了研究。地震是在水平面中双向应用的,而忽略了垂直地震动分量。剪力式基础隔离基准建筑物建模为三维线性弹性结构,在每个楼层均具有三个自由度。借助恒定平均加速度Newmark-Beta方法对基准建筑物进行时域动态分析,并通过四阶Runge-Kutta方法处理非线性隔离力。通过性能标准和重要结构响应参数(例如地板加速度,基础位移等)的石灰历史响应,研究了基础隔震基准建筑物与层状橡胶轴承相结合时的均匀隔震和混合隔震。观察到可变滑动隔离器的性能与常规FPS相比,它具有更好的性能,因为它们具有变化的特性,使它们能够根据隔离器的位移来改变隔离器力,从而提高了结构的性能。 VFPS有效地控制了较大的隔离器位移,VFPI和VCFPS改善了隔离器位移成本方面的超级结构响应。还可以观察到,与基准测试建筑物的均匀隔离相比,混合隔离相对更好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号