首页> 外文期刊>Journal of dairy research >Effect of storage and preservation of milk samples on the response of microbial inhibitor tests
【24h】

Effect of storage and preservation of milk samples on the response of microbial inhibitor tests

机译:牛奶样品的保存和保存对微生物抑制剂测试响应的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to evaluate the effect of storage time (4 ℃) on milk samples and the use of azidiol as preservative on the results of microbial inhibitor tests used to detect antimicrobials in milk. For this purpose, 16 milk bulk samples divided into two aliquots, preservative-free and with azidiol, spiked with 12 concentrations of amoxicillin, ampicillin, penicillin G and oxytetracycline, were used. The milk samples were analysed using the BRT MRL, Delvotest MCS Accelerator and Eclipse 100 at 0, 24,48 and 72 h stored at 4 ℃. The logistic regression model was applied to study the effect of storage time (ST), preservative (P) and their interaction (ST × P). At a concentration equivalent to the Detection Limit (DL), the positive results of microbial inhibitor tests do not remain stable during storage time. These results are more reproducible if samples are stored with a preservative. At Maximum Residue Limits (MRLs) concentration microbial inhibitor tests can detect penicillin for up to 72 h of storage. For oxytetracycline, the BRT MRL and Delvotest MCS tests presents DL exceeding the MRL, therefore they are not sensitivity to this tetracycline (0% positive results). By contrast Eclipse 100, whose DL is lower than the MRL, gave 100% positive results during the 72 h storage period. It can be concluded that it would be convenient to store milk samples with azidiol at 4 ℃ and to carry out analyses within the first 48 h since milk sampling.
机译:这项研究的目的是评估贮藏时间(4℃)对牛奶样品的影响,以及在用于检测牛奶中抗菌素的微生物抑制剂测试结果中使用叠氮二醇作为防腐剂的效果。为此,使用了16个散装牛奶样品,分为两个等分试样,分别不含防腐剂和叠氮二醇,加标了12种浓度的阿莫西林,氨苄青霉素,青霉素G和土霉素。使用BRT MRL,Delvotest MCS Accelerator和Eclipse 100在4℃下储存的0、24、48和72 h对牛奶样品进行分析。应用logistic回归模型研究储存时间(ST),防腐剂(P)及其相互作用(ST×P)的影响。在等于检测限(DL)的浓度下,微生物抑制剂测试的阳性结果在储存期间不会保持稳定。如果样品与防腐剂一起储存,这些结果将更具可重复性。在最大残留限量(MRL)浓度下,微生物抑制剂测试可以检测青霉素长达72小时的储存时间。对于土霉素,BRT MRL和Delvotest MCS测试显示的DL超过MRL,因此它们对这种四环素不敏感(0%阳性结果)。相比之下,其DL低于MRL的Eclipse 100在72小时的存储期内给出100%的阳性结果。可以得出结论,从牛奶采样开始的前48小时内,将牛奶样品与叠氮二醇一起存储在4℃并进行分析是很方便的。

著录项

  • 来源
    《Journal of dairy research》 |2013年第4期|475-484|共10页
  • 作者单位

    Instituto de Ciencia y Tecnologfa Animal, Universitat Politecnica de Valencia, Camino de Vera, s 46022 Valencia, Spain;

    Centra Superior de Investigacion en Salud Publica, Avd. Cataluna, 21 46020 Valencia, Spain;

    Catedra de Bioffsica, Facultad de Ciencias Veterinarias, Universidad Nacional del Literal-R.P.L., Kreder2805, 3080 Esperanza, Argentina;

    Instituto de Ciencia y Tecnologfa Animal, Universitat Politecnica de Valencia, Camino de Vera, s 46022 Valencia, Spain;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Microbial inhibitor tests; storage; azidiol; antibiotics;

    机译:微生物抑制剂测试;存储;叠氮二醇抗生素类;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号