This study presents the development of the ductile detail of a T-stiffener added to existing moment connections. The seismic behavior of the aforementioned detail was investigated analytically as well as experimentally. A new design criterion is developed for a horizontal element of T-stiffener. Results of this study indicate that the crack propagation is eliminated using the new proposed procedure. This means that by utilizing a fillet weld as a replacement for a CJP groove weld in joining the T-stiffener to a beam flange eliminates crack propagation at the tip of the T-stiffener on the beam flange. In the experimental program, the specimens performed well during the test and reached a total story drift angle of 6% radians before experiencing 20% strength degradation.
机译:这项研究提出了添加到现有弯矩连接中的T型加劲肋的延性细部的发展。对上述细节的地震行为进行了分析和实验研究。为T型加劲肋的水平单元开发了新的设计准则。这项研究的结果表明,使用新提出的程序可以消除裂纹扩展。这意味着,在将T型加劲肋连接到梁法兰时,通过使用角焊缝代替CJP坡口焊缝,可以消除T型加劲肋尖端在梁法兰上的裂纹扩展。在实验程序中,试样在测试过程中表现良好,并且在经历20%的强度下降之前达到了6%弧度的总层漂移角。