The use of concrete-filled steel tubular (CFST) columns and reinforced concrete (RC) shear wall mixed structures has attracted the interest of structural engineers. The connection between the composite columns, the shear-wall edge members and concrete wall are critical. The connection behavior at the interface of the different elements has been a major subject of this study. Therefore, ten specimens were tested to investigate the force-slip behavior between a CFST column and an RC shear wall. Also a simplified model (two models: model with nonlinear springs, simple truss model) for predicting the force-slip relation based on experimental and numerical studies was presented. (C) 2015 Elsevier Ltd. All rights reserved.
机译:钢管混凝土(CFST)柱和钢筋混凝土(RC)剪力墙混合结构的使用引起了结构工程师的兴趣。复合柱,剪力墙边缘构件和混凝土墙之间的连接至关重要。在不同元素的界面处的连接行为一直是这项研究的主要主题。因此,测试了十个样本以研究CFST柱和RC剪力墙之间的力滑行为。并给出了基于实验和数值研究的简化模型(两种模型:带有非线性弹簧的模型,简单桁架模型),用于预测力-滑移关系。 (C)2015 Elsevier Ltd.保留所有权利。