A series of tests on concrete-filled steel tubes (CFSTs) with reinforcing bars or angles under axial tension were conducted in this study. In total, thirteen full scale specimens having length of 4000 mm and outer diameter of 400 mm were tested. The steel tubes were fabricated from structural steel with nominal yield strength of 460 MPa and nominal plate thickness of 4 or 6 mm. Reinforcing bars or angles were placed inside the steel tube before the filling of concrete. The behaviour and strengths of CFSTs with reinforcing bars or angles under axial tension were investigated. The load-axial displacement curves and load-strain curves were obtained. The cracks in the core concrete were also investigated from the failure specimens. The tensile strengths are compared with the design strengths calculated using the current AISC standard. Design equations were proposed for the tensile strengths and elastic tensile stiffness of CFSTs with reinforcing bars or angles. (C) 2017 Elsevier Ltd. All rights reserved.
机译:在这项研究中,对在轴向张力下具有钢筋或角钢的钢管混凝土(CFST)进行了一系列测试。总共测试了13个长度为4000 mm,外径为400 mm的满刻度样品。钢管由标称屈服强度为460 MPa,标称板厚为4或6 mm的结构钢制成。在填充混凝土之前,将钢筋或角钢放置在钢管内。研究了带有钢筋或角钢的钢管混凝土在轴向拉伸下的行为和强度。得到了载荷-轴向位移曲线和载荷-应变曲线。还从破坏样本中研究了芯混凝土中的裂缝。将拉伸强度与使用当前AISC标准计算出的设计强度进行比较。针对具有钢筋或角钢的CFST的抗拉强度和弹性抗拉刚度,提出了设计方程。 (C)2017 Elsevier Ltd.保留所有权利。