On the basis of plastic limit analysis, this paper proposes a novel, simple and unified interaction equation (N-M) for Concrete-filled Steel Tube (CFST) columns subjected to combined compression and bending. A unique feature of the new N-M equation is that the single equation is valid for a range of columns that can be solid, hollow, circular, polygonal, short or long. The single equation can also apply to columns under both room and elevated temperatures. Validations against independent laboratory test, analytical and numerical results are carried out to assess the accuracy and applicability of the equation. The new equation agrees well with most of the results used in the comparisons. It can be concluded that the simple and unified equation can be used in practical design with sufficient accuracy. (C) 2018 Elsevier Ltd. All rights reserved.
机译:在塑性极限分析的基础上,提出了一种受压弯折组合的钢管混凝土柱(CFST)的新颖,简单统一的相互作用方程(N-M)。新的N-M方程式的独特之处在于,该方程式对于一系列可以是实心,空心,圆形,多边形,短或长的列均有效。单个方程式还可以应用于室温和高温下的色谱柱。针对独立的实验室测试,分析和数值结果进行了验证,以评估该方程式的准确性和适用性。新公式与比较中使用的大多数结果非常吻合。可以得出结论,该简单统一的方程式可以在实际设计中以足够的精度使用。 (C)2018 Elsevier Ltd.保留所有权利。