This paper presents a new method for calculating fire resistance of axially loaded Concrete-Filled Steel Tube (CFST) columns with different section profiles, including circular and polygonal sections that can be solid and hollow. The uniqueness of this new method is that the fire resistance is calculated on the basis of the average temperature of the columns' cross-sections. This is done by taking the bearing capacity of a CFST column at room temperature as a special case of the bearing capacity of the same column at the start of a fire. The equivalent strength and equivalent elastic modulus in relation to the average temperature of steel and concrete are investigated, and a unified method of calculation is proposed, by which the calculation of fire resistance of a CFST column can be divided into two steps, i.e. (a) calculation of the equivalent strength and elastic modulus of steel and concrete at elevated temperature based on the average temperature, and (b) calculation of fire resistance using the formulas at room temperature by replacing the equivalent material strength and elastic modulus at elevated temperature. The two sets of formulas for calculating fire resistance of CFST columns are given by combining the unified method, respectively, with Eurocode 4 and the authors' previous work. The proposed formulas and procedure are validated through comparisons with the experimental results of a number of solid and hollow CFST columns with circular and square sections.
机译:本文提出了一种新的计算截面截面轮廓(包括可以是实心和空心的圆形截面和多边形截面)的钢管混凝土(CFST)柱的耐火性的新方法。这种新方法的独特之处在于,其耐火性是根据柱子横截面的平均温度计算得出的。这是通过将CFST柱在室温下的承载能力作为火灾开始时同一根柱的承载能力的特例来完成的。研究了与钢材和混凝土平均温度有关的等效强度和等效弹性模量,并提出了统一的计算方法,通过这种方法,CFST柱的耐火性计算可分为两个步骤,即(a )基于平均温度计算高温下钢和混凝土的等效强度和弹性模量,以及(b)通过替换高温下的等效材料强度和弹性模量,使用室温下的公式计算耐火性。通过将统一方法与欧洲规范4和作者先前的工作相结合,给出了计算CFST柱耐火性的两组公式。通过与许多具有圆形和正方形截面的实心和空心CFST柱的实验结果进行比较,验证了所提出的公式和步骤。

著录项

  • 来源
    《Engineering Structures》 |2014年第15期|12-22|共11页
  • 作者单位

    School of Civil Engineering, Wuhan University, Wuhan 430072, China,Shenzhen Graduate School, Harbin Institute of Technology, Shenzhen 518055, China;

    Shenzhen Graduate School, Harbin Institute of Technology, Shenzhen 518055, China;

    School of Civil Engineering, Wuhan University, Wuhan 430072, China,Department of Engineering, Lancaster University, Lancaster, LA1 4YR, UK;

    Shenzhen Graduate School, Harbin Institute of Technology, Shenzhen 518055, China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Solid and hollow concrete filled steel tube; Circular and polygonal; Fire resistance; Average temperature; Unified method;

    机译:实心和空心混凝土填充钢管;圆形和多边形;防火性能;平均温度;统一方法;