In this study, three concrete-filled steel tubular (CFST) column-steel beam bolted joints with external reinforcing diaphragm were tested under cyclic loading using 1/2 scaled specimens, and the influence law of steel beam size and tie plate of high-strength bolts on the failure modes were discussed. The ABAQUS program was used to establish the three-dimensional solid finite element models of the joints, and the joint models were then verified by the test data. Taking the welded rigid joint with external reinforcing diaphragm as the benchmark, a connection detailing of bolted rigid joint and a method for classifying the joint were proposed. The stiffness, bearing capacity and plastic energy dissipation of the bolted joints with different structural detailing and reinforcing measures were compared and analyzed. The obtained results show that the bolted joints with external reinforcing diaphragm can be classified as semi-rigid joint. The stiffness and bearing capacity of the bolted joint can almost be equivalent with the welded rigid joint counterparts, when the external reinforcing diaphragm with stiffeners was connected to the steel beam using four rows of bolts and simultaneously setting web stiffeners at the beam ends. With the above configuration, the total plastic energy dissipation of the bolted joint is over 80% of that of the welded rigid joint counterpart, and the steel beam is found to be the main component contributing the plastic energy dissipation.(c) 2021 Elsevier Ltd. All rights reserved.
机译:在这项研究中,使用1/2缩放标本,在循环载荷下进行三种混凝土钢管(CFST)柱 - 钢束螺栓接头,并在循环载量下进行循环载荷测试,以及高强度钢梁尺寸和扎带的影响规律讨论了失败模式的螺栓。 ABAQUS程序用于建立关节的三维实体有限元模型,然后通过测试数据验证联合模型。提出使用外部加强隔膜作为基准,提出了螺栓固定刚性接头的连接细节和用于分类联合的方法。比较和分析了具有不同结构细节和增强措施的螺栓接头的刚度,承载力和塑料能量耗散。所得结果表明,具有外部加强隔膜的螺栓接头可以被分类为半刚性接头。当使用四排螺栓连接到加强件的外部加强隔膜时,螺栓接头的刚度和承载力与焊接的刚性接头对应物几乎相当于焊接刚性接头对应物。利用上述配置,螺栓接头的总塑性能量耗散量超过焊接刚性接头对应物的80%,并且发现钢梁是有助于塑料能量耗散的主要成分。(c)2021 Elsevier Ltd 。 版权所有。

著录项

  • 来源
    《Journal of Constructional Steel Research》 |2021年第8期|106729.1-106729.18|共18页
  • 作者单位

    Cent South Univ Sch Civil Engn Changsha 410075 Hunan Peoples R China|Engn Technol Res Ctr Prefabricated Construct Ind Changsha 410075 Peoples R China;

    Cent South Univ Sch Civil Engn Changsha 410075 Hunan Peoples R China;

    Cent South Univ Sch Civil Engn Changsha 410075 Hunan Peoples R China|Engn Technol Res Ctr Prefabricated Construct Ind Changsha 410075 Peoples R China;

    Cent South Univ Sch Civil Engn Changsha 410075 Hunan Peoples R China;

    Wuhan Univ Sci & Technol Sch Urban Construct Wuhan 430065 Hubei Peoples R China;

    Hunan Architectural Design Inst Co Ltd Changsha 410012 Hunan Peoples R China;

    Hunan Acad Res Co Ltd Changsha 410011 Hunan Peoples R China;

    China Construct Fifth Engn Div Co Ltd Changsha 410007 Hunan Peoples R China;

    Cent South Univ Sch Civil Engn Changsha 410075 Hunan Peoples R China;

    Cent South Univ Sch Civil Engn Changsha 410075 Hunan Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Concrete-filled steel tube; External reinforcing diaphragm; Bolted connection; Rigid joint; Plastic energy dissipation;