首页> 外文期刊>Journal of Constructional Steel Research >Fire behaviour of thin-walled steel tube confined reinforced concrete stub columns under axial compression
【24h】

Fire behaviour of thin-walled steel tube confined reinforced concrete stub columns under axial compression

机译:薄壁钢管的火灾行为在轴压下狭窄钢筋混凝土柱柱

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Thin-walled steel tube confined reinforced concrete columns are new-type composite members and the static and seismic performance of these columns have been extensively investigated in recent decades. There are, however, very limited studies on the fire behaviour of the steel tube confined reinforced concrete stub columns subjected to axial compression. In this paper, experimental and numerical studies on the fire response of steel tube confined reinforced concrete stub columns under axial compression are presented. A total of eight specimens with varying wall thicknesses of steel tube and load ratios were tested to failure under the ISO-834 standard fire. Temperature distribution, axial deformation, failure modes, and fire duration were recorded in the fire tests. Finite element (FE) models were established using ABAQUS to estimate the fire behaviour and the models were validated by comparing with the measured results. Parametric studies were then performed on the fire resistance of thin-walled steel tube confined reinforced concrete stub columns and the considered parameters include diameter of steel tube, wall thickness of steel tube, load ratio, reinforcement ratio, material strength, and concrete cover thickness. The studies show that the load ratio and diameter of steel tube are two key factors governing fire resistance of thin-walled steel tube confined reinforced concrete stub columns. Based on test and numerical results, a design approach was proposed to predict the temperature distribution and loading capacity of thin-walled steel tube confined reinforced concrete stub columns under ISO-834 standard fire. (c) 2020 Elsevier Ltd. All rights reserved.
机译:薄壁钢管限制钢管混凝土柱是新型复合构件,近几十年来,这些柱的静态和地震性能已被广泛调查。然而,对钢管的火焰行为的研究非常有限,钢管被施加轴向压缩的钢管钢筋混凝土柱。本文提出,介绍了轴压下钢管狭窄钢管钢管防火响应的实验和数值研究。在ISO-834标准火灾下,测试了总共八个具有不同壁厚的钢管和载荷比的标本。在防火试验中记录了温度分布,轴向变形,故障模式和火灾持续时间。使用ABAQUS建立有限元(FE)模型来估计火灾行为,并通过与测量结果进行比较验证模型。然后对薄壁钢管的耐火电阻进行参数化研究局限性钢管混凝土支柱柱,所考虑的参数包括钢管直径,钢管壁厚,负荷比,加固比,材料强度和混凝土覆盖厚度。研究表明,钢管的负荷比率和直径是控制薄壁钢管局部钢管的耐火电阻的两个关键因素。基于试验和数值结果,提出了一种设计方法,以预测薄壁钢管的温度分布和装载能力在ISO-834标准火灾下的薄壁钢管受限增强混凝土柱。 (c)2020 elestvier有限公司保留所有权利。

著录项

  • 来源
    《Journal of Constructional Steel Research》 |2020年第9期|106180.1-106180.16|共16页
  • 作者单位

    Chongqing Univ Sch Civil Engn Chongqing 400045 Peoples R China|Imperial Coll London Dept Civil & Environm Engn London SW7 2AZ England;

    Chongqing Univ Sch Civil Engn Chongqing 400045 Peoples R China|Chongqing Univ Minist Educ Key Lab New Technol Construct Cities Mt Area Chongqing 400045 Peoples R China;

    Chongqing Univ Sch Civil Engn Chongqing 400045 Peoples R China|Chongqing Univ Minist Educ Key Lab New Technol Construct Cities Mt Area Chongqing 400045 Peoples R China;

    Chongqing Univ Sch Civil Engn Chongqing 400045 Peoples R China|Chongqing Univ Minist Educ Key Lab New Technol Construct Cities Mt Area Chongqing 400045 Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Thin-walled steel tube confined concrete columns; Fire tests; Finite element modelling; Parametric studies; Fire resistance; Design approach;

    机译:薄壁钢管紧孔混凝土柱;防火试验;有限元建模;参数研究;耐火;设计方法;