首页> 外文期刊>Journal of Composites for Construction >In-Plane Shear Behaviors of Constrained Masonry Walls Externally Retrofitted with BFRP
【24h】

In-Plane Shear Behaviors of Constrained Masonry Walls Externally Retrofitted with BFRP

机译:BFRP外部加固的约束砌体墙的平面内剪切行为

获取原文
获取原文并翻译 | 示例
       

摘要

This study presents an experimental study on responses of eight constrained masonry walls with tie columns and ring beams, subjected to in-plane cyclic loading before and after being retrofitted with basalt-fiber-reinforced polymer (BFRP). Among these eight walls, two without any strengthening measures served as reference specimens; two were directly strengthened with horizontal and diagonal BFRP strips after they were constructed; and the rest were tested to defined damage levels and then repaired for retesting. The opening in the wall, the layer of the BFRP strip, and the vertical compression level were considered in the test design. Experimental results showed different failure modes of the specimens. Details of testing results were discussed regarding strength and drift, hysteretic characteristics, stiffness degradation, energy dissipation, and BFRP strip strains. A performance comparison analysis was also conducted between the constrained masonry walls and the unreinforced ones. Finally, a calculation method was proposed to estimate the ultimate lateral strength of BFRP retrofitted masonry walls.
机译:这项研究提供了一个实验研究,研究了用玄武岩纤维增强聚合物(BFRP)改造前后受平面内循环荷载作用的带约束柱和环形梁的8个受约束砌体墙的响应。在这八堵墙中,有两堵没有采取任何加强措施。建造后,其中两个直接用水平和对角BFRP条进行了加固。其余的经过测试以达到规定的损坏水平,然后进行维修以进行重新测试。在测试设计中考虑了墙的开口,BFRP条带的层和垂直压缩水平。实验结果表明,试样的破坏模式不同。讨论了有关强度和漂移,滞后特性,刚度降低,能量耗散和BFRP条形应变的详细测试结果。还对受约束的砖石墙和未加固的砖石墙之间进行了性能比较分析。最后,提出了一种计算方法来估计BFRP加固砌体墙的极限横向强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号