This paper presents the results of the flexural testing to destruction of two cast iron girders preserved during the demolition of a railway bridge in Scotland. The 151-year-old girders were reinforced with ultrahigh modulus carbon fiber polymer composite (CFRP) plates in 2004. The CFRP plates on one girder were damaged during the demolition and were rendered completely ineffective before testing. The girders were 9 m long and were be tested in four-point bending to failure which gave a unique opportunity to compare the behavior of unreinforced and reinforced cast iron at full-scale. Fragments of cast iron and CFRP that remained after the flexural testing were be used to prepare test specimens and were used to determine material properties. The tests demonstrated the considerable benefits of CFRP strengthening (an increase in load-bearing capacity of 43.9% and an increase in stiffness of 31%) and confirmed that the CFRP was fully bonded to the cast iron until close to the point of failure. The test results have been compared with theoretical and original design predictions that showed that the theoretical predictions were remarkably accurate and the design predictions were conservative as is required for a safe design. This paper includes details of the girders, the test rig, and test procedure, and presents in detail the test results that include the failure mechanisms and will discuss the benefits obtained from the CFRP strengthening of cast iron girders.(C) 2020 American Society of Civil Engineers.
机译:本文介绍了在苏格兰拆迁铁路桥拆迁期间保存的两个铸铁梁的弯曲试验结果。 2004年,使用超高模量碳纤维聚合物复合物(CFRP)板加固了151岁的梁。在拆除期间,一缩梁上的CFRP板损坏,在测试前完全无效。梁长9米,在四点弯曲到失效的4点进行测试,这给了一个独特的机会,可以在满量程中比较未原始和增强铸铁的行为。铸铁和CFRP的碎片用于制备试样并用于确定材料性质。该试验证明了CFRP强化(承载能力增加43.9%的增加,刚度增加31%)并证实了CFRP完全键合在铸铁直至靠近故障点。测试结果与理论和原始设计预测进行了比较,表明理论上的预测非常准确,并且安全设计所需的设计预测是保守的。本文包括梁,试验台和测试程序的细节,并详细介绍了包括故障机制的测试结果,并将讨论从铸铁梁的CFRP加强所获得的益处。(c)2020年美国社会土木工程师。

著录项

  • 来源
    《Journal of Composites for Construction》 |2020年第6期|05020005.1-05020005.9|共9页
  • 作者

    Moy Stuart;

  • 作者单位

    Univ Southampton Fac Engn & Phys Sci Southampton SO17 1BJ Hants England;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号