首页> 外文期刊>Journal of biomedical optics >ACA-Pro: calibration protocol for quantitative diffuse reflectance spectroscopy. Validation on contact and noncontact probe- and CCD-based systems
【24h】

ACA-Pro: calibration protocol for quantitative diffuse reflectance spectroscopy. Validation on contact and noncontact probe- and CCD-based systems

机译:ACA-Pro:定量漫反射光谱的校准方案。验证基于接触和非接触式探头和CCD的系统

获取原文
获取原文并翻译 | 示例
       

摘要

We have developed an adaptive calibration algorithm and protocol (ACA-Pro) that corrects from the instrumental response of various spatially resolved diffuse reflectance spectroscopy (DRSsr) systems to enable the quantification of absorption and scattering properties based on a Monte Carlo-based look-up-table approach. The protocol involves the use of a calibration reference base built with measurements of a range of different diffusive intralipid phantoms. Moreover, an advanced strategy was established to take into account the experimental variations with an additional measurement of a common solid material, allowing the use of a single calibration reference base for all experiments. The ACA-Pro is validated in contact and noncontact probe-based DRSsr systems. Furthermore, the first results of a setup replacing the probe with a CCD detector are shown to confirm the robustness of the approach.
机译:我们已经开发了一种自适应校准算法和协议(ACA-Pro),可以从各种空间分辨的漫反射光谱(DRSsr)系统的仪器响应中进行校正,从而能够基于基于Monte Carlo的查找量化吸收和散射特性表方法。该协议涉及使用校准参考库,该参考库通过对一系列不同的弥散性脂质体内模型进行测量而构建。此外,建立了一种先进的策略来考虑到实验变化以及对普通固体材料的额外测量,从而允许对所有实验使用单个校准基准。 ACA-Pro已在基于接触式和非接触式探头的DRSsr系统中得到验证。此外,显示了用CCD检测器代替探头的设置的最初结果,证实了该方法的鲁棒性。

著录项

  • 来源
    《Journal of biomedical optics》 |2016年第6期|065003.1-065003.14|共14页
  • 作者单位

    CEA-LETI, Minatec Campus, 17 Rue des Martyrs, F38054 Grenoble, Cedex 9, France;

    CEA-LETI, Minatec Campus, 17 Rue des Martyrs, F38054 Grenoble, Cedex 9, France;

    CEA-LETI, Minatec Campus, 17 Rue des Martyrs, F38054 Grenoble, Cedex 9, France;

    UPMC University Paris 06, UMR8237, Laboratoire Jean Perrin, F-75005, Paris, France,CNRS, UMR8237, Laboratoire Jean Perrin, F-75005, Paris, France;

    CEA-LETI, Minatec Campus, 17 Rue des Martyrs, F38054 Grenoble, Cedex 9, France;

    UPMC University Paris 06, UMR8237, Laboratoire Jean Perrin, F-75005, Paris, France,CNRS, UMR8237, Laboratoire Jean Perrin, F-75005, Paris, France;

    CEA-LETI, Minatec Campus, 17 Rue des Martyrs, F38054 Grenoble, Cedex 9, France;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    calibration; spectroscopy; reflectance; optical properties; quantification;

    机译:校准;光谱学反射率光学性质量化;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号