Various software-based measurement systems can be used for live sound measurements with music or speech signals in occupied concert halls with sufficient accuracy. However, for some special applications as measuring the performance of a ground-stacked bass array component of a multiple component sound reinforcement system in an occupied hall, these systems can't be used directly, since it is not possible to run a bass array alone during a concert. Two simple methods to obtain the subwoofers' impulse response using program signal measurements of a full range sound reinforcement system are proposed. In the first case the desired impulse response results from subtraction of full system impulse responses with and without subwoofers running. In the second a small delay is added to the subwoofers' signal, their impulse response is then calculated from the difference between the response of the full system with and without the delay. The comparison of both methods' results with a reference sweep measurement is presented, limitations and accuracy are discussed.
机译:可以使用各种基于软件的测量系统以足够的精度在占用的音乐厅中对音乐或语音信号进行现场声音测量。但是,对于某些特殊应用(如在占用的大厅中测量多分量扩声系统中地面堆叠的低音阵列组件的性能),由于无法单独运行低音阵列,因此无法直接使用这些系统。在音乐会上。提出了两种使用全音域扩声系统的程序信号测量来获得低音炮冲激响应的简单方法。在第一种情况下,期望的脉冲响应是通过在运行和不运行低音炮的情况下减去整个系统的脉冲响应而得出的。在第二秒中,将较小的延迟添加到低音炮的信号,然后根据整个系统在有无延迟的情况下的响应差来计算其脉冲响应。介绍了两种方法的结果与参考扫描测量的比较,讨论了局限性和准确性。