...
首页> 外文期刊>Journal of Applied Biomechanics >Evaluating the Acromion Marker Cluster as a Method for Measuring Scapular Orientation in Children With Brachial Plexus Birth Palsy
【24h】

Evaluating the Acromion Marker Cluster as a Method for Measuring Scapular Orientation in Children With Brachial Plexus Birth Palsy

机译:评价Acromion标记群集作为测量臂丛神经性麻痹患儿肩cap骨方向的一种方法

获取原文
获取原文并翻译 | 示例

摘要

Several studies have described using an acromion marker cluster for measuring scapular orientation in healthy adults performing planar motions. It is unknown whether the acromion marker cluster method will provide the same level of accuracy in children with brachial plexus birth palsy. This study compared this method to palpation for calculating scapular orientation in children with brachial plexus birth palsy performing clinically relevant movements. Scapular orientation in ten patients was determined by palpation and an acromion marker cluster in neutral and six Modified Mallet positions. RMSEs and mean relative errors were calculated. Resultant RMSEs ranged from 5.2 degrees to 21.4 degrees. The averages of the mean relative errors across all positions for each axis were 177.4% for upward/downward rotation, 865.0% for internal/external rotation, and 166.2% for anterior/posterior tilt. The acromion marker cluster method did not accurately measure scapular rotation relative to the total movement on an individual or group basis in the population. With most relative errors over 100%, the acromion marker cluster method often produced errors larger than the actual measured motion. The accuracy of the acromion marker cluster method limits its use as a clinical tool for measuring scapular kinematics on children with brachial plexus birth palsy.
机译:几项研究描述了使用肩峰标记物簇来测量健康成年人进行平面运动时的肩cap骨方向。肩峰标记聚类方法能否在臂丛神经性麻痹患儿中提供相同水平的准确度尚不清楚。这项研究将这种方法与触诊进行了比较,以计算臂丛神经麻痹患儿执行临床相关动作的儿童的肩cap骨方向。通过触诊和中性和六个改良式槌头位置的肩峰标记簇确定十名患者的肩cap骨方向。计算RMSE和平均相对误差。所得RMSE范围为5.2度到21.4度。每个轴在所有位置上的平均相对误差的平均值分别为:向上/向下旋转为177.4%,内部/外部旋转为865.0%,向前/向后倾斜为166.2%。肩峰标记群集方法不能准确地测量相对于总体中个体或群体运动的肩cap骨旋转。在大多数相对误差超过100%的情况下,肩峰标记群集方法通常产生的误差大于实际测量的运动。肩峰标记簇方法的准确性限制了其作为测量臂丛神经麻痹患儿肩cap运动学的临床工具的用途。

著录项

  • 来源
    《Journal of Applied Biomechanics 》 |2014年第1期| 128-133| 共6页
  • 作者单位

    Biomechanics and Movement Science Program, University of Delaware, Newark, DE;

    Biomechanics and Movement Science Program, University of Delaware, Newark, DE;

    Department of Orthopaedic Surgery, Temple University, Philadelphia, PA, Upper Extremity Center of Excellence, Shriners Hospital for Children, Philadelphia, PA;

    Department of Orthopaedic Surgery, Temple University, Philadelphia, PA, Upper Extremity Center of Excellence, Shriners Hospital for Children, Philadelphia, PA;

    Department of Kinesiology and Applied Physiology, University of Delaware, Newark, DE;

    Department of Kinesiology and Applied Physiology, University of Delaware, Newark, DE;

    Biomechanics and Movement Science Program and Department of Kinesiology and Applied Physiology, University of Delaware, Newark, DE;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    shoulder; scapulothoracic; kinematics;

    机译:肩;肩oth孔运动学;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号