In this paper, we explore a variety of aqueous digestion techniques for the determination of gold, in a wide variety of mineral matrices. Acid digestion methods, based upon modified aqua regia in which a larger proportion of nitric acid (5 : 1 HNO3 : HCl) is involved, competes effectively with fire assay to deliver accurate and precise values for gold in a fraction of the time. Using this ratio of acids, simple sand-bath digestions deliver recoveries of 95 to 98% of gold certified reference values, after a digestion time of approximately 35 minutes. Focused infrared digestions, however, take only 15 minutes, and deliver higher recoveries, in the range of 95 to 104% of gold reference values. An ultrasonic digestion with 1,3-dibromo-5,5-dimethylhydantoin acting as a source of bromine, delivered mediocre recoveries of gold. Gold determinations were conducted using inductively coupled plasma-mass spectrometry (ICP-MS). Solvent extraction of gold from digestion solutions effectively preconcentrate gold and significantly reduces interference from major elements, except for those samples containing high concentrations of iron. The use of 2-octanone as extraction solvent exhibited greater sensitivity than the use of the conventional solvent, methyl isobutyl ketone (MIBK). Although 2-ethylhexanol was also effective at extracting gold, its lengthy time for phase separation and memory effects, which increased wash-in and wash-out times, made it a less attractive extraction medium. For solvent extraction methods, microwave induced plasma-atomic emission spectrometry (MP-AES) was used for the determination of gold.
机译:在本文中,我们探索了多种水溶消化技术,用于测定多种矿物基质中的金。酸消解法基于改良的王水,其中涉及较大比例的硝酸(5:1 HNO3:HCl),可与火试验有效竞争,从而在短时间内提供准确和精确的金值。使用这种比例的酸,简单的沙浴消解在约35分钟的消解时间后可实现95%至98%的金标准参考值的回收率。但是,聚焦的红外消解仅需15分钟,回收率更高,达到金参考值的95%至104%。用1,3-二溴-5,5-二甲基乙内酰脲作为溴源进行超声波消解,回收的金量中等。金的测定使用电感耦合等离子体质谱法(ICP-MS)进行。从消化液中溶剂萃取金可有效地预浓缩金,并显着减少主要元素的干扰,但那些样品中的铁含量较高。使用2-辛酮作为萃取溶剂比使用常规溶剂甲基异丁基酮(MIBK)具有更高的灵敏度。尽管2-乙基己醇在提取金方面也很有效,但由于其相分离和记忆效应的时间过长(增加洗入和洗出时间),因此它的吸引力不大。对于溶剂萃取方法,微波诱导等离子体原子发射光谱法(MP-AES)用于测定金。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号