首页> 外文期刊>Journal of Analytical Atomic Spectrometry >A low cost and sensitive procedure for lead screening in human whole blood with sequential injection-hydride generation-atomic fluorescence spectrometry
【24h】

A low cost and sensitive procedure for lead screening in human whole blood with sequential injection-hydride generation-atomic fluorescence spectrometry

机译:序贯注射氢化物发生-原子荧光光谱法低成本,灵敏地检测人全血中的铅

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

An automated sequential injection hydride generation(HG) atomic fluorescence spectrometric (AFS) method was developed, with the aim of screening blood lead levels for Chinese citizens, especially for children. Lead hydride was generated from acid solution, with potassium ferricyanide as an oxidizing agent, by reaction with alkaline tetrahydroborate solution. The hydride was separated from the reaction medium in a gas - liquid separator (GLS(1)) and swept directly into the atomizer. A thorough scrutiny was made of the various factors, including the modi. cation of the AFS instrument and related parameters, the various wet digestion protocols, the variables of the flow system and the reaction conditions. Under the optimized conditions the blank signal was satisfactorily minimized, giving rise to a limit of detection of 0.014 mg l(-1), defined as 3 times the blank standard deviation divided by the slope of calibration graph, and a RSD value of 0.7% (at the 2.0 mug l(-1) level, n = 11), along with a sampling frequency of 120 h(-1). The sensitivity of the procedure was found to be significantly superior to those obtained by HG-atomic emission spectrometry (AES), direct sampling electrothermal atomic absorption spectrometry (ETAAS), tungsten. lament atomizer ETAAS, and quartz tube atomizer HG-AAS; it was even lower than those by in-atomizer-trapping HG-ETAAS and comparable to ICPMS-based methods. The accuracy and practical applicability of the procedure were validated by analysing certified reference materials of frozen cattle blood GBW 09139 and GBW 09140, and further demonstrated by spiking recoveries of lead in human whole blood samples.
机译:开发了一种自动顺序注射氢化物发生(HG)原子荧光光谱法(AFS)的方法,目的是筛查中国公民尤其是儿童的血铅水平。以铁氰化钾为氧化剂,通过与碱性四氢硼酸盐溶液反应,由酸性溶液生成氢化铅。在气液分离器(GLS(1))中将氢化物与反应介质分离,并直接扫入雾化器。对包括modi在内的各种因素进行了详尽的审查。 AFS仪器的阳离子和相关参数,各种湿消解方案,流动系统的变量和反应条件。在优化的条件下,空白信号令人满意地最小化,检测限为0.014 mg l(-1),定义为空白标准偏差除以校准曲线的斜率的3倍,RSD值为0.7% (在2.0杯l(-1)的水平下,n = 11),以及120 h(-1)的采样频率。发现该方法的灵敏度明显优于通过HG原子发射光谱法(AES),直接采样电热原子吸收光谱法(ETAAS),钨获得的灵敏度。哀叹雾化器ETAAS和石英管雾化器HG-AAS;它甚至比雾化器内捕集的HG-ETAAS低,与基于ICPMS的方法相当。该方法的准确性和实际适用性通过分析冷冻牛血GBW 09139和GBW 09140的认证参考材料得到验证,并通过在人体全血样品中回收铅而进一步证明。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号