An internal standard method coupled with a gravimetric standard addition method (ISM-SAM) with a single spiked sample was proposed as a strategy for elemental measurements. Equations are given for measurement of the element based on its ratios to the internal-standard in the spiked sample and to the non-spiked sample. Optimization of the relative quantity of the standard solution was carried out to improve the precision of the measurement, the results obtained showed that a high-precision measurement could be obtained when the concentration of the measurand in the spiked sample was over 2-fold of that in the non-spiked sample. Measurement of Cu in a test solution was performed in parallel to the measurement by inductively coupled plasma mass spectrometry (ICP-MS) and isotope dilution (ID-) ICP-MS, and the results indicate that the present method has similar reliability to those of ID-ICP-MS and ICP-MS. Furthermore, the ISM-SAM method was applied to the analysis of P in two certified reference materials (CRMs) issued by the National Metrology Institute of Japan (NMIJ) with different mono-isotopic elements (Be, Al, Sc, As, Y, Rh, and Cs) as the internal standard elements. All of the results agreed with the certified values of the CRMs. The results neither depended on the atomic number nor depended on the ionization rate of the internal standard element. The present method was also applied to the analysis of other elements in CRMs of tea leaf powder, seaweeds, and swordfish tissue, providing accurate results.
机译:提出了将内标方法与重量标准加入法(ISM-SAM)结合使用单个加标样品作为元素测量的策略。根据元素与加标样品和未加标样品中内标物的比率,给出了用于元素测量的方程式。优化标准溶液的相对量以提高测量精度,获得的结果表明,当加标样品中被测量物质的浓度超过标准溶液的两倍时,可以进行高精度的测量。在未加标样品中。与通过电感耦合等离子体质谱法(ICP-MS)和同位素稀释(ID-)ICP-MS进行的测定平行进行测定溶液中的Cu,结果表明本方法的可靠性与ID-ICP-MS和ICP-MS。此外,ISM-SAM方法还用于分析由日本国家计量学会(NMIJ)发行的两种认证参考物质(CRM)中的P,这些参考物质具有不同的单一同位素元素(Be,Al,Sc,As,Y, Rh和Cs)作为内标元素。所有结果均与CRM的认证值一致。结果既不依赖于原子序数也不依赖于内标元素的电离率。本方法还可用于茶叶粉,紫菜和箭鱼组织CRM中其他元素的分析,从而提供准确的结果。

著录项

  • 来源
    《Journal of Analytical Atomic Spectrometry》 |2012年第6期|p.1000-1006|共7页
  • 作者

    Yanbei Zhu; Koichi Chiba;

  • 作者单位

    National Metrology Institute of Japan, National Institute of Advance Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan;

    National Metrology Institute of Japan, National Institute of Advance Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号