This paper presents the design and performance of a compact dilution sampler (CDS) for characterizing fine particle emissions from stationary sources. The sampler is described, along with the methodology adopted for its use. Dilution sampling has a number of advantages, including source emissions that are measured under conditions simulating stack gas entry and mixing in the ambient atmosphere. This is particularly important for characterizing the semivolatile species in effluents as a part of particulate emissions. The CDS characteristics and performance are given, along with sampling methodology. The CDS was compared with a reference dilution sampler. The results indicate that the two designs are comparable for tests on gas-fired units and a diesel electrical generator. The performance data indicate that lower detection limits can be achieved relative to current regulatory methods for particulate emissions. Test data for the fine particulate matter (PM2.5) emissions are provided for comparison with U.S. Environment Protection Agency (EPA) Conditional Test Method 040 for filterable particulate matter (FPM) and the EPA Method 202 for condensable particulate matter. This comparison showed important differences between methods, depending on whether a comparison is done between in situ FPM determinations or the sum of such values with condensable PM from liquid filled impingers chilled in an ice bath. These differences are interpretable in the light of semivolatile material present in the stack effluent and, in some cases, differences in detection and quantification limits. Determination of emissions from combustors using liquid fuels can be readily achieved using 1-hr sampling with the CDS. Emissions from gasfired combustors are very low, requiring careful attention to sample volumes. Sampling volumes corresponding with 6-hr operation were used for the combined mass and broad chemical speciation. Particular attention to dilution sampler operation with clean dilution air also is essential for gas-fired sources.
机译:本文介绍了用于表征固定源细颗粒排放的紧凑型稀释采样器(CDS)的设计和性能。描述了采样器及其使用的方法。稀释采样具有许多优势,包括在模拟烟囱气体进入和在环境大气中混合的条件下测量的源排放。这对于表征废水中的半挥发性物质作为颗粒物排放的一部分尤其重要。给出了CDS的特性和性能,以及抽样方法。将CDS与参考稀释取样器进行比较。结果表明,这两种设计在燃气装置和柴油发电机的测试中具有可比性。性能数据表明,相对于当前的颗粒物排放监管方法,可以实现更低的检测限。提供了细颗粒物(PM2.5)排放的测试数据,以便与美国环境保护局(EPA)的可过滤颗粒物(FPM)的条件测试方法040和可凝结颗粒物的EPA方法202进行比较。这种比较显示了方法之间的重要差异,这取决于是在原位FPM测定之间进行比较,还是在冰浴中冷却的充满液体的撞击器中将这些值与可冷凝PM进行比较。这些差异可以根据烟囱流出物中存在的半挥发性物质以及在某些情况下检测限和定量限的差异来解释。使用CDS进行1小时采样可以轻松确定使用液体燃料的燃烧器的排放。燃气燃烧器的排放非常低,需要特别注意样品量。结合质量和广泛的化学形态,使用了与6小时操作相对应的采样体积。对于燃气源,尤其要注意使用干净的稀释空气进行稀释采样器的操作。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号