首页> 外文期刊>Japanese Journal of Applied Physics. Part 1, Regular Papers & Short Notes >Generation Mechanism of Heat Flows near the Stack as a Prime Mover in a Thermoacoustic Cooling System
【24h】

Generation Mechanism of Heat Flows near the Stack as a Prime Mover in a Thermoacoustic Cooling System

机译:热声冷却系统中作为原动机的烟囱附近的热流产生机理

获取原文
获取原文并翻译 | 示例
           

摘要

Temperature variations in a thermoacoustic cooling system consisting of a loop-tube were investigated. The heat flows were discussed using observation results of the temperature variations in the tube. The regenerator, stack 1, was employed as a prime mover and stack 2 as a heat pump. At the cooling point, on the stack 2, the temperature decrease of 22℃ was confirmed. Heat flows did not appear in the location far from the stack 1 except near the stack 2. On the other hand, heat flows induced by the sound energy flow and acoustic streaming, appeared near the stack 1. The sound energy flow was caused by the thermoacoustic effect. The directions of the sound energy flow and heat flow were opposite, according to the energy conservation law. In the loop-tube, the strong nonlinearity was observed in the generated sound, and the acoustic streaming was induced.
机译:研究了由回路管组成的热声冷却系统中的温度变化。使用管中温度变化的观察结果讨论了热流。蓄热室1用作原动机,蓄热室2用作热泵。在堆2的冷却点,确认温度降低了22℃。除了靠近电池堆2以外,没有在远离电池堆1的位置出现热流。另一方面,由声能流和声流引起的热流出现在电池堆1附近。热声效应。根据能量守恒定律,声能流和热流的方向相反。在环状管中,在产生的声音中观察到强烈的非线性,并且引起声流。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号