首页> 外文期刊>European Transactions on Electrical Power >Third-Order Passive Load Identification Under Non-Sinusoidal Conditions
【24h】

Third-Order Passive Load Identification Under Non-Sinusoidal Conditions

机译:非正弦条件下的三阶被动载荷识别

获取原文
获取原文并翻译 | 示例
           

摘要

this paper presents an extension of the well known load identification method, valid under non-sinusoidal condi- tions, which makes use of a 2~nd -order passive circuit and an auxiliary voltage or current generator. The proposed solution is similar, but uses a 3~rd-order passive circuit. This allows to identify the passive circuit components with positive or negative parameters, according to the aim of the identification (load modeling or compensation). Moreover, the proposed approach keeps the orthogonality between current/voltage components and removes the Indetermination which occurs, with the 2~nd-order approach, in the case of sinusoidal operation. As an application Example, the proposed approach is applied to the design of a hybrid compensation system including active and Passive filtering.
机译:本文介绍了众所周知的负载识别方法的扩展,该方法在非正弦条件下有效,它利用了二阶无源电路和辅助电压或电流发生器。所提出的解决方案是相似的,但是使用了三阶无源电路。根据识别的目的(负载建模或补偿),这可以识别具有正或负参数的无源电路组件。此外,所提出的方法保持了电流/电压分量之间的正交性,并消除了在正弦操作情况下使用二阶方法时出现的不确定性。作为一个应用实例,所提出的方法被应用于包含有源和无源滤波的混合补偿系统的设计。