Series arcing, which can occur at any point of a line or neutral conductor between the switchboard and a load (mechanically damaged conductor, clamps in the switchboard or in the equipment, connections in outlets, receptacles, and switches), is the most frequent electrical cause of fire. This paper presents an original and simple algorithm for the detection of series arcing, based on permanent spectral analysis of the circuit current signal. A prototype of a simple and cheap detector of series arcing has also been developed. The target group for the application of the protective device are residential premises, the most numerous and most critical buildings in which series arcing occurs. In such buildings a range of potential loads is limited, which enables the application of the presented simple algorithm. Its applicability is confirmed through an extensive set of tests.
机译:串联电弧是最常见的电气故障,可能在配电盘和负载之间的线路或中性导体的任何点发生(机械损坏的导体,配电盘或设备中的夹具,插座,插座和开关的连接)。起火的原因。本文基于电路电流信号的永久频谱分析,提出了一种新颖,简单的串联电弧检测算法。还开发了一种简单且便宜的串联电弧探测器的原型。应用保护装置的目标人群是住宅场所,是发生串联电弧的数量最多,最关键的建筑物。在这样的建筑物中,潜在负载的范围是有限的,这使得所提出的简单算法的应用成为可能。它的适用性通过一系列广泛的测试得到了证实。