...
首页> 外文期刊>International Orthopaedics >Effect of antibiotic loading on the shear strength at the stem–cement interface (Shear strength of antibiotic loaded cement)
【24h】

Effect of antibiotic loading on the shear strength at the stem–cement interface (Shear strength of antibiotic loaded cement)

机译:抗生素负荷对干水泥界面抗剪强度的影响(抗生素负荷水泥的抗剪强度)

获取原文
获取原文并翻译 | 示例

摘要

The purpose of this study was to investigate the effects of addition of antibiotics into cement powder on the shear properties of the cement–metal interface. The approach involved adding 800 mg of teicoplanin to 40 g bone cement powder in the t-800 group, 1,600 mg teicoplanin in the t-1,600 group, and no antibiotic in the control group. Industrially prepared bone cement containing 500 mg of gentamicin was used as group g-500. Each group consisted of ten samples. Cement–metal interfaces were produced using metal discs with porous surfaces (1 μm) and templates at the third minute. Shear stability of specimens was measured in a material testing machine. The ANOVA test was used for comparison between the mean shear results of each group. Results showed that mean shear stress to failure values were 12.28 ± 3.35 MPa for the control group, 11.72 ± 3.09 MPa for the t-800 group, 13.25 ± 2.36 MPa for the t-1,600 group and 13.09 ± 2.58 MPa for the g-500 group. No statistically significant differences were found between results of the groups. Results of the study have proven that addition of 1,600 mg of teicoplanin or 500 mg gentamycin in 40 g of bone cement does not decrease the shear strength at the cement–metal interface significantly on the day of application.
机译:这项研究的目的是研究在水泥粉中添加抗生素对水泥-金属界面的剪切性能的影响。该方法包括在t-800组中将800 mg替考拉宁添加到40 g骨水泥粉中,在t-600组中添加1,600 mg替考拉宁,而对照组不添加抗生素。工业制备的含有500 mg庆大霉素的骨水泥用作g-500组。每组由十个样品组成。在第三分钟使用具有多孔表面(1μm)的金属圆盘和模板生产水泥-金属界面。在材料试验机中测量样品的剪切稳定性。 ANOVA测试用于比较各组的平均剪切结果。结果显示,对照组的平均剪切应力至破坏值分别为:12.28±3.35 MPa,t-800组为11.72±3.09 MPa,t-1600组为13.25±2.36 MPa,g-500为13.09±2.58 MPa。组。两组结果之间没有发现统计学上的显着差异。研究结果证明,在40 g骨水泥中添加1,600 mg替考拉宁或500 mg庆大霉素在使用当天不会显着降低水泥-金属界面的剪切强度。

著录项

  • 来源
    《International Orthopaedics 》 |2008年第4期| 437-441| 共5页
  • 作者单位

    Istanbul Medical Faculty Department of Orthopaedics and Traumatology Istanbul University 34093 Topkapi Istanbul Turkey;

    Department of Orthopaedics and Traumatology Vehbi Koc Foundation American Hospital Istanbul Turkey;

    Department of Orthopaedics and Traumatology Acibadem Bakirkoy Hospital Istanbul Turkey;

    Faculty of Mechanical Engineering Istanbul Technical University Istanbul Turkey;

    Faculty of Mechanical Engineering Istanbul Technical University Istanbul Turkey;

    Istanbul Medical Faculty Department of Orthopaedics and Traumatology Istanbul University 34093 Topkapi Istanbul Turkey;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号