The purpose of this paper was to evaluate the results of acetabular revisions with the use of an oblong revision cup that is designed with its longitudinal diameter elongated relative to its transverse diameter. Between 1996 and 2001, 62 hips in 60 patients underwent an acetabular revision with the insertion of a LOR acetabular component. Seven hips were lost to follow-up or the patients died; the remaining 55 hips (53 patients) remained in follow-up for an average of 7.2 years (range: 5.0–10.1 years). One socket was revised for aseptic loosening, and another was operated on for a late polyethylene liner dissociation. The average Harris hip score (HHS) improved from 34 to 79. Results were rated as excellent in 16 hips, good in 28, fair in six and poor in three. Radiographic analysis demonstrated an improvement in the average vertical displacement of the hip centre: 49 hips had a well-fixed, bone-ingrown cup and four had a stable fibrous union. For large superolateral acetabular bone deficiencies, this implant facilitated a complex reconstruction without the need for bulk structural acetabular bone grafts, provided good clinical results and showed satisfactory stability at the midterm follow-up.
机译:本文的目的是通过使用长方形改良杯来评估髋臼改良的结果,该长方形改良杯的纵向直径相对于横向直径拉长。在1996年至2001年之间,对60例患者的62髋进行了髋臼翻修并插入了LOR髋臼组件。失去了七个髋关节或患者死亡。其余55髋(53例患者)平均随访7.2年(范围:5.0-10.1年)。对一个插座进行了无菌松动的修改,对另一个插座进行了后期聚乙烯内衬的解离。哈里斯(Harris)髋关节平均得分(HHS)从34提高到79。结果被评为16髋优秀,28良好,6中等,3差。影像学分析表明,髋中心的平均垂直位移有所改善:49髋固定良好,骨长入杯,四髋具有稳定的纤维连接。对于较大的髋臼上颌骨缺损,这种植入物无需复杂的髋臼骨结构移植即可进行复杂的重建,提供了良好的临床效果,并在中期随访中显示出令人满意的稳定性。

著录项

  • 来源
    《International Orthopaedics》 |2008年第2期|189-193|共5页
  • 作者单位

    Second Orthopaedic Clinic Department of Orthopaedics and Traumatology Plastic Surgery and Rehabilitation University of Florence CTO - Largo Palagi 1 50139 Florence Italy;

    Department of Orthopaedics and Traumatology University of Cagliari Cagliari Italy;

    Second Orthopaedic Clinic Department of Orthopaedics and Traumatology Plastic Surgery and Rehabilitation University of Florence CTO - Largo Palagi 1 50139 Florence Italy;

    Second Orthopaedic Clinic Department of Orthopaedics and Traumatology Plastic Surgery and Rehabilitation University of Florence CTO - Largo Palagi 1 50139 Florence Italy;

    Second Orthopaedic Clinic Department of Orthopaedics and Traumatology Plastic Surgery and Rehabilitation University of Florence CTO - Largo Palagi 1 50139 Florence Italy;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号