PVTx measurements for the R116 + CO2 system for four isotherms (283, 304, 325 and 346 K) were performed. In total, 16 runs were performed in a pressure range from 5100 to 140 kPa. Seven runs along four isotherms in a pressure range from 3400 to 280 kPa were performed for pure hexafluoroethane (R116), and the second and third virial coefficients were derived. The values of the virial coefficients for CO2 were adopted from our previous measurements. The second and third virial coefficients along with the second and third cross-virial coefficients were derived from the mixture results. The Burnett apparatus was calibrated using helium. The experimental uncertainty in second and third virial coefficients was estimated to be within ±2 cm3· mol−1 and ±500 cm6 ·mol −2, respectively.
机译:对R116 + CO2 系统进行了四个等温线(283、304、325和346 K)的PVTx测量。在5100至140 kPa的压力范围内总共进行了16次运行。对纯六氟乙烷(R116)在3400至280 kPa的压力范围内沿着四个等温线进行了7次运行,得出了第二和第三维里系数。二氧化碳的维里系数值是根据我们先前的测量结果得出的。从混合结果中得出第二和第三维里系数以及第二和第三交叉维里系数。 Burnett仪器使用氦气校准。第二和第三维里系数的实验不确定性分别估计在±2 cm3 ·mol-1 和±500 cm6 ·mol -2 之内。